© 2008 Therma-Stor LLC 

 Manual P/N TS- 235 4/08

Rx

Rx

n

  Free-standing dehumidification  

for your home.

n  

Includes installation, operating 
and safety instructions, warranty 
information and all ancillary 
products.

Read and save these instructions.

For small usage:

P.O. Box 8680 Madison, WI 53708 

 TOLL-FREE 1-800-533-7533 

 www.thermastor.com 

 [email protected]

INSTALLER’S & OWNER’S MANUAL

HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER

P/N 4023673  •  Serial No.________________________ Install Date:___________ 
Sold by:

Summary of Contents for Santa-Fe Rx

Page 1: ...ons warranty information and all ancillary products n Read and save these instructions For small usage P O Box 8680 Madison WI 53708 TOLL FREE 1 800 533 7533 www thermastor com sales thermastor com INSTALLER S OWNER S MANUAL HVAC INSTALLER PLEASE LEAVE MANUAL FOR HOMEOWNER P N 4023673 Serial No ________________________ Install Date ___________ Sold by ...

Page 2: ...nstructions carefully before installing and using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Santa Fe Rx Dehumidifier 1 Specifications Part Number 4023673 Blower 230 CFM 0 0 WG Power 630 Watts 80 F and 60 RH Supply Voltage 115 volt 1 phase 60 Hz Current Draw 5 4 Amps Energy Factor 2 45 l kw Operating Temp 45 F Min 95 F Max 70 F recommended Siz...

Page 3: ...Pump failure will cause the unit to stop dehumidifying via a safety switch 2 4 Optional Reservoir Container If the condensate discharge hose cannot be routed to a drain or outside it can empty into a conveniently located container This container supplied by the customer can be any size greater than 1 2 gallon It can be emptied manually or by a pump supplied by the customer CAUTION It is strongly r...

Page 4: ...as it loads up with contaminates It starts out black then turns pink then brown and finally white It is best changed when it passes the brown stage and begins to turn white as it has lost most of its effectiveness at that point Actual filter size of the carbon filter is 19 38 wide x 15 38 high x 2 88 deep The 88 deep pleated filter is the same nominal size and is installed downstream of the carbon...

Page 5: ...ion 3 Defective blower Sec 5 5 4 Blower switch defective Evaporator coil frosted continuously low dehumidifying capacity 1 Defrost thermostat loose or defective Sec 5 8 2 Low refrigerant charge 3 Dirty air filter or air flow restricted Sec 4 1B 5 4 Refrigerant Charging If the refrigerant charge is lost due to service or a leak a new charge must be accurately weighed in If any of the old charge is ...

Page 6: ... test kit If it indicates a burn out follow EPA regulations for disposing of the old refrigerant and oil Follow standard procedures for replacing a burned out compressor These would include replacement of the liquid line filter drier and addition of an oversized suction line filter drier if it was a running burn out Several changes of the liquid and suction filter driers may be necessary to cleans...

Page 7: ...SANTA FE Rx WIRING DIAGRAM 7 Santa Fe Rx Installer s Owner s Manual PART NO REV 4023857 C Made in U S A Therma Stor LLC Madison WI 53708 800 533 7533 www thermastor com ...

Page 8: ...e Set not shown 6 4024912 1 Capacitor Run 25 Mfd 7 4021589 2 Capillary Tube 050 I D X 144 O D X 28 Long 8 4023604 4 Caster Swivel 2 9 4021396 1 Condenser Coil 10 4026703 1 Compressor ITEM PART NO QTY DESCRIPTION 11 4023649 1 Condensate Pump Low Profile 12 4023661 1 Cord Wire Harness not shown 13 4021470 1 Defrost Control Thermostat 14 4021648 1 Defrost Thermostat Mounting Clip 15 4021395 1 Evapora...

Page 9: ...ilter Test The optional 95 efficiency and HEPA filters have long lives when prefitered by the standard pleated inlet filter they can last many years in certain conditions How long they last can however vary widely depending upon the following Unit run time air contamination level and standard inlet filter cleanliness Due to the optional filters expense it can be costly to change them prematurely T...

Page 10: ...t instructions 5 Blower switch is set in the off position at the factory See manual for blower operation options 6 Install the filter as shown in Figure Air flow arrow must point down 7 Lower the top down so the keyhole slots in the top drop over the posts Slide the top until the catch latches to the strike as shown in Figure SANTA FE Rx SET UP INSTRUCTIONS 10 Santa Fe Rx Installer s Owner s Manua...

Page 11: ...ts related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim to Therma Stor such that Therma Stor receives such claim prior to the end of the appli...

Page 12: ...duced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680 Madison WI 53708 Phone 608 222 5301 Fax 608 222 1447 Web www thermastor com Email sales thermastor com ...