CAPINTEC, INC.
CAPTUS
®
600
CAUTION
The unit contains a Lithium Battery. This should be disposed of in accordance with local and
national regulations.
CAUTION
The user should always verify the validity of any measurement or test result in order to
minimize measurement errors.
NOTE
It is recommended that periodic (every five years) re-calibration of the unit be performed by
Capintec’s Authorized Service Center (reference CHAPTER 20: CLEANING AND
MAINTENANCE) to guarantee that the instrument's high reliability is maintained.
GENERAL SAFETY TIPS
•
Unplug the equipment before cleaning it. Use only a damp cloth; do not use solvents
or aerosol cleaners.
•
To protect the equipment from overheating, make sure none of the openings (vents)
on the Readout Unit or the Printer are blocked. Do not use the equipment directly in
front of a radiator or heat register.
•
The print head, in the printer, can get quite hot when it’s been printing for a length of
time. Do not touch the print head until it has had a chance to cool.
•
Do not use the equipment near water, or spill liquids of any kind into the equipment.
•
Be sure that your power source matches the rating listed on the Isolation
Transformer.
•
The
CAPTUS
®
600 power cord has a grounded, 3-prong plug as a safety feature, and
it will only fit into a grounded outlet. Do not use an adapter to defeat the grounding.
•
To avoid damaging the power cord, do not place anything on it or place it where it will
be walked on. If the cord becomes damaged, replace it immediately.
•
Aside from the routine maintenance described in this manual, do not try to service
this equipment yourself. Do not make any adjustments other than those outlined in
this manual, as you may in-validate the calibration or cause damage requiring
extensive repair work. Refer servicing to qualified service personnel.
•
Do not subject the Detectors to rough handling, or rapid temperature changes, as the
NaI Scintillation Crystal can be damaged. Do not use the equipment directly in front of
a radiator, heat register, or air conditioning duct.
1-6 SAFETY
November
07
Содержание CAPTUS 600
Страница 2: ......
Страница 40: ......
Страница 62: ......
Страница 77: ...CAPINTEC INC CAPTUS 600 Page 1 November 07 ACCEPTANCE QUALITY ASSURANCE TESTS 6 15...
Страница 78: ...CAPINTEC INC CAPTUS 600 Page 2 Page 3 6 16 ACCEPTANCE QUALITY ASSURANCE TESTS November 07...
Страница 90: ......
Страница 102: ......
Страница 112: ...CAPINTEC INC CAPTUS 600 Figure 9 15 9 10 THYROID UPTAKE ONE CAPSULE METHOD November 07...
Страница 120: ...CAPINTEC INC CAPTUS 600 Figure 10 11 10 8 THYROID UPTAKE TWO CAPSULES METHOD November 07...
Страница 131: ...CAPINTEC INC CAPTUS 600 Figure 11 16 November 07 THYROID UPTAKE STANDARD CAPSULE METHOD 11 11...
Страница 132: ......
Страница 150: ...CAPINTEC INC CAPTUS 600 Figure 13 11 13 8 WIPE TEST November 07...
Страница 152: ......
Страница 162: ...CAPINTEC INC CAPTUS 600 Figure 15 5 15 4 LAB TESTS URINE TEST November 07...
Страница 167: ...CAPINTEC INC CAPTUS 600 Figure 16 5 November 07 LAB TESTS BLOOD TESTS 16 5...
Страница 171: ...CAPINTEC INC CAPTUS 600 Figure 16 9 November 07 LAB TESTS BLOOD TESTS 16 9...
Страница 175: ...CAPINTEC INC CAPTUS 600 Figure 16 14 November 07 LAB TESTS BLOOD TESTS 16 13...
Страница 176: ......
Страница 186: ......
Страница 208: ......
Страница 214: ......
Страница 216: ......
Страница 217: ......
Страница 218: ......