CAPINTEC, INC.
CAPTUS
®
3000
CHAPTER 11
BIOASSAY
I 131/I 125 and I 123/1 125 Cross Contamination ..................................... 11-9
ADDING STAFF MEMBERS .......................................................................... 11-9
EDITING STAFF MEMBER INFORMATION ................................................. 11-11
DELETING STAFF MEMBER ....................................................................... 11-11
MAKING MEASUREMENTS ......................................................................... 11-13
VIEWING AND PRINTING REPORTS........................................................... 11-16
CAUTION:
To ensure optimum performance of CAPTUS
®
3000, before
using the
Bioassay
module, perform the System Setup Procedures as outlined in
CHAPTER 4: GENERAL SETUP.
INTRODUCTION
Bioassays are generally performed whenever radiation workers are occupationally exposed
to unsealed or high activity sources of I 131, I 125 and I 123 on a regular basis. This test is
used to monitor exposure levels for these workers. Any measured activity outside the normal
limits will be flagged. As part of the procedure, it also determines the system efficiency for
these isotopes.
Notes: Staff Members can only be added or removed by the Administrator. The Administrator
has access to all Staff Members’ Bioassay data.
Staff Members can only access his/her own Bioassay data. Each Staff Member must
be added to the Users by the Administrator before he/she can access their Bioassay
data.
Users who are not Staff Members cannot access Bioassay data.
To access the Bioassay module, click the
button or press
Alt+B
on the
CAPTUS
®
3000 Main screen. Figure 11-1 Main Bioassay Screen will appear. The
Staff
Member Directory
box will be empty if there are currently no existing staff members in the
database. Added staff members will appear in this box with their name, the Staff ID and date
of birth. By default, the first record is selected. The
Latest Results
box below shows the
results of the most recent measurements performed on the selected staff member. The icons
at the top of the screen provide functions to add, edit or delete data, to change measurement
setup and to view test reports.
November 13
BIOASSAY
11-1
Содержание CAPTUS 3000
Страница 2: ......
Страница 10: ...CAPINTEC INC CAPTUS 3000 INDEX WARRANTY DECLARATION OF CONFORMITY TOC 8 TABLE OF CONTENTS July 14...
Страница 14: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 22: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 86: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 124: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 266: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 284: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 292: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 304: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 334: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 336: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...
Страница 337: ......
Страница 338: ...CAPINTEC INC CAPTUS 3000 This page intentionally left blank...