CDE360 Vector Control AC Drive Chapter 5 Parameter List Table
-
80
-
F1 Auto Reset
Code
Name
Range
Default
Step
Description
F1.00
Fault auto reset times
0~30
0
1
F1.01
Time interval of fault auto reset
0.1~100.0
1.0
0.1Sec
F1.02
DO action during fault auto reset
00~11
00
1
Unit's digit:
Fault indication terminals
0: No action during fault reset process
1: Action during fault reset
Ten's digit:
restart after automatic fault reset
0: Not auto restart
1: having auto restart
H0 System Parameters
Code
Name
Range
Default
Step
Description
H0.00
User password
0000~9999
0000
1
H0.01
LED display running
parameters 1
0~65535
31
1
Bit0: Running frequency(1)
Bit1: Setting frequency(2)
Bit2: Dc-link voltage(4)
Bit3: Output current(8)
Bit4: Output voltage(16)
Bit5: Output torque(32)
Bit6: Output power(64)
Bit7: AI1 voltage(128)
Bit8: AI2 voltage(256)
Bit9: AI3 voltage(512)
Bit10: X terminals status(1024)
Bit11: Y terminals status(2048)
Bit12: PLC stage(4096)
Bit13: PID setting(8192)
Bit14: PID feedback(16384)
Bit15: Count value(32768)
H0.02
LED display running
parameters 2
0~2047
0
1
Bit0: FI input frequency(1)
Bit1: Linear speed(2)
Bit2: Load speed(4)
Bit3: Actual length(8)
Bit4: remaining running time(16)
Bit5: Main frequency A (32)
Bit7: FO output frequency(128)
Bit8:Feedback speed(256)
Bit9:motor speed(512)
Bit10:Multi-Pump Control status
words(1024)
H0.03
LED display stop
parameters
1~65535
3
1
Bit0: Setting frequency(1)
Bit1: Dc-link voltage(2)
Bit2: X terminals status(4)
Bit3: Y terminals status(8)
Bit4: AI1 voltage(16)
Bit5: AI2 voltage(32)
Bit6: AI3 voltage(64)
Bit7: FI input frequency(128)
Bit8: PID setting(256)
Bit9: PID feedback(512)
Bit10: PLC stage(1024)
Bit11: Pulse input frequency(2048)
Bit12: actual length(4096)
Bit13
~
Bit15: reserve
H0.04
①
Parameter initial option
0~4
0
1
0: No Operation 1: Restore to factory default value, not include motor parameters
2: Restore to factory default value, including motor parameters
3: Parameter upload to keypad 4: Parameter download from keypad
H0.05
Menu display selection
0~2
0
1
0: Display all parameters 1: Display user-defined parameters