CDE360 Vector Control AC Drive Chapter 6 Parameters Description
-
88
-
A0.12
Range: -10.00~10.00
Default: 0.00
AI2 voltage
Unit: V
It display AI2 voltage, the covert mode same as
A0.11
.
A0.13
Range: -10.00~10.00
Default: 0.00
AI3 voltage
Unit: V
It display AI3 voltage, the covert mode same as
A0.11
.
A0.14
Range: 0.00~10.00
Default: 0.00
AO1 voltage
Unit: V
It display AO1 voltage, the covert mode same as
A0.11
.
A0.15
Range: 0.00~10.00
Default: 0.00
AO2 voltage
Unit: V
It display AO2 voltage, the covert mode same as
A0.11
.
A0.16
Range: 0~1023
Default: 0
X terminals
status word
Each bit corresponds to a
X
terminal status.
0: Disable 1: Enable
Bit0: X1
(
1
)
Bit5: X6
(
32
)
Bit1: X2
(
2
)
Bit6: X7
(
64
)
Bit2: X3
(
4
)
Bit7: X8
(
128
)
Bit3: X4
(
8
)
Bit8: X9
(
256
)
Bit4: X5
(
16
)
Bit9: X10
(
512
)
For example: A0.16 = 55, The number of 55 is consist of (32+16+4+2+1),
So the status of X6,X5,X3,X2 and X1 are validated.
A0.17
Range: 0~511
Default: 0
Y terminals
status word
Each bit corresponds to a
Y
terminal status.
0: Disable 1: Enable
Bit0: Y1
(
1
)
Bit5: T3
(
32
)
Bit1: Y2
(
2
)
Bit6: T4
(
64
)
Bit2: Y3
(
4
)
Bit7: T5
(
128
)
Bit3: T1
(
8
)
Bit8: T6
(
256
)
Bit4: T2
(
16
)
For example: A0.17 = 29, The number of 29 is consist of (16+8+4+1), So
the status of T2,T1,Y3 and Y1 are validated.
A0.18
Range: 0.00~100.00
Default: 0.00
FI frequency
Unit: kHz
It displays X6/FI high speed pulse input frequency.
A0.19
Range: 0.00~100.00
Default: 0.00
FO frequency
Unit: kHz
It displays Y2/FO high speed pulse output frequency.