(16) Operation Panel Unit / LCD Unit removal
a) Release the thirteen hooks of the operation panel, then remove the panel without breaking the hooks.
b) Remove the seven screws, then disconnect the flexible cable and connector.
c) Disconnect the LCD flexible cable, then release the two hooks (circled in red below) to remove the LCD unit.
1-32
Содержание PIXMA MP530
Страница 5: ...Part 1 MAINTENANCE ...
Страница 34: ... Right side c Disconnect the connector for the solenoid 1 29 ...
Страница 51: ... Service test print sample 1 46 ...
Страница 56: ... System data list sample 1 51 ...
Страница 57: ... Error transmission report sample 1 52 ...
Страница 60: ...Part 2 TECHNICAL REFERENCE ...
Страница 73: ...Part 3 APPENDIX ...