V. MALFUNCTION TROUBLESHOOTING
Perform troubleshooting according to the malfunction diagnosis flowchart (Figure 4-1-1). If an
“malfunction” is found, the defective part must be located and rectified by the following proce-
dure.
V-1.
No AC power
<Possible causes>
1) Blown fuse (FU101)
Action:
Refering to page 3-22 in Chapter 3, replace the fuse (FU101).
2) Defective engine controller PCB
Action:
Replace the engine controller PCB.
V-2.
No DC power
<Possible causes>
1) No AC power is supplied.
Action:
Make a check according to 5-1 “No AC power”.
2) Overcurrent/overvoltage detection circuit activated
Action:
If the problem is not rectified after the power switch is turned OFF and then ON
again, find the cause of activation of the overcurrent/overvoltage detection circuit
in the power supply unit. Wait for two minutes or more before turning the power
back ON.
3) Blown fuse (FU102)
Action:
Refering to page 3-22 in Chapter 3, replace the fuse (FU102).
4) Defective engine controller PCB
Action:
Replace the engine controller PCB.
CHAPTER 4
4 - 16
Содержание LBP-800
Страница 8: ......
Страница 68: ......
Страница 74: ......
Страница 110: ......
Страница 127: ...VI MOTOR SOLENOID A Locations M001 Main motor SL001 Pick up solenoid Figure 3 6 1 CHAPTER 3 3 17 SL001 M001 ...
Страница 129: ...VII PCBs A Locations Interface controller PCB Engine controller PCB Display PCB Figure 3 7 1 CHAPTER 3 3 19 ...
Страница 134: ......
Страница 136: ......
Страница 164: ......
Страница 165: ...APPENDIX I GENERAL TIMING CHART A 1 II GENERAL CIRCUIT DIAGRAM A 3 III LIST OF SIGNALS A 5 IV MESSAGES TABLE A 7 ...
Страница 166: ......
Страница 168: ......
Страница 178: ...The printing paper contains 70 waste paper PRINTED IN JAPAN IMPRIME AU JAPON 0899AB0 50 CANON INC ...