8
Code
Description
Remedy
E248-
0000
Reader backup data read error
The verification of the reader backup
1. Check the connector connection
between the Reader Controller PCB
4. Replace the Reader Motor
(M10).
5. Replace the Reader
Controller PCB (PCB3).
6. Replace the Main
Controller PCB (PCB2).
E202-
0002
CIS Unit home position detection error
The CIS Unit did not come off the CIS HP
Sensor (PS24).
1. Check the connection of
the Flexible Cable between
the Reader Controller PCB
(PCB3) and the Main
Controller PCB (PCB2).
2. Replace the Flexible Cable.
3. Replace the CIS HP
Sensor (PS24).
4. Replace the Reader Motor
(M10).
5. Replace the Reader
Controller PCB (PCB3).
6. Replace the Main
Controller PCB (PCB2).
E240-
0000
Controller communication error
A serial communication error was detected
during normal operation.
1. Check the connector
connection between the DC
Controller PCB (PCB1) and
the Main Controller PCB
(PCB2).
2. Replace the DC Controller
PCB (PCB1).
E240-
0001
Controller communication error
A serial communication error was detected
during printing.
1. Check the connector
connection between the DC
Controller PCB (PCB1) and
the Main Controller PCB
(PCB2).
2. Replace the DC Controller
PCB (PCB1).
E246
System error
Contact the service company
office
E247
System error
Contact the service company
office