23
Unable to recognize the
Surf board
E731-
3001
Error in Main Controller
PCB
Failure in Surf initialization
1. Check connection of Main Controller PCB.
2. Replace Main Controller PCB (PCB2).
E731-
3002
Error in Main Controller
PCB
Failure in Surf initialization
1. Check connection of Main Controller PCB.
2. Replace Main Controller PCB (PCB2).
E731-
3015
Error in Main Controller
PCB
Although it works normally
at the software side, there
is no video data into CL1-G
1. Check connection of Main Controller PCB.
2. Replace Main Controller PCB (PCB2).
E732-
0010
Scanner communication
error
Vertical Synchronizing
signal detection error
1. Check the connection of the Connector with the
Reader. 2. Check the power of the Reader (check if
the initialization operation is executed at startup). 3.
Replace the Reader Relay PCB. 4. Replace the
Main Controller PCB.
E740-
0002
Ethernet Board error
Invalid MAC address
1. Replace the LAN card
E740-
0003
Ethernet Board error
Invalid MAC address
1. Replace the LAN card
E743-
0000
DDI communication error
SCI error, reception data
NG, reception timeout,
SEQ timeout error
1. Turn OFF and then ON the power.
2. Check connection of the cable between the
Reader and the Controller.
3. Check voltage (+24V and +12V) on the Reader
Controller PCB.
4. Replace the Reader Controller PCB (PCB3).
5. Replace Main Controller PCB (PCB2).
E744
Language file error
E746-
0021
Engine ID error
Self-check error of Image
Analysis Board (HW board
used for PCAM)
1. Replace the Image Analysis Board (HW board
used for PCAM).
2. As a temporary measure, remove the Image
Analysis Board and get in service mode:
COPIER > OPTION > LCNS-TR > ST-JBLK (Lv2);
set ST-JBLK from 1 to 0,
and turn OFF and then
ON the power.
E746-
0022
Engine ID error
Wrong version of Image
Analysis Board
1. Update the firmware of the Image Analysis
Board.
2. As a temporary measure, remove the Image
Analysis Board and get in service mode: