2
Drawer, connector disconnection,
open circuit)
3. Check the connection between the
AC Driver PCB (PCB4) and Fixing
Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB
(PCB4).
6. Replace the DC Controller PCB
(PCB1).
E001-
0002
Fixing Assembly high temperature error
The Fixing Sub Thermistor (THM2)
detected 295 degrees C or higher for
200msec or longer on end.
1. Perform the following to clear the
error: COPIER > FUNCTION >
CLEAR > ERR in the Service Mode;
then, turn the power switch to OFF
and then ON.
2. Check the connection of the Fixing
Assembly. (Connection error of the
Drawer, connector disconnection,
open circuit)
3. Check the connection between the
AC Driver PCB (PCB4) and Fixing
Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB
(PCB4).
6. Replace the DC Controller PCB
(PCB1).
E002-
0000
Fixing Assembly temperature rise error
1. The Fixing Main Thermistor (THM1)
detected the temperature of lower than
115 degrees C for 400msec or longer on
end 6.0 seconds later after detecting 100
degrees C.
2. The Fixing Main Thermistor (THM1)
detected the temperature of lower than
150 degrees C for 400msec or longer on
end 6.0 seconds later after detecting 140
degrees C.
1. Perform the following to clear the
error: COPIER > FUNCTION >
CLEAR > ERR in the Service Mode;
then, turn the power switch to OFF
and then ON.
2. Check the connection of the Fixing
Assembly. (Connection error of the
Drawer, connector disconnection,
open circuit)
3. Check the connection between the
AC Driver PCB (PCB4) and Fixing
Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB
(PCB4).
6. Replace the DC Controller PCB
(PCB1).
E003-
Fixing Assembly temperature decrease
1. Perform the following to clear the