20
Code
Description
Remedy
E713-
0000
Error in communication with the
Finisher (communication retry
failure)
The communication did not connect
again although the error retry was
executed after failing to
communicate with the Finisher.
1. Check the installation of the Host
Machine and the Finisher.
2. Check the connector connection
between the DC Controller PCB (PCB1)
and the Finisher Controller PCB (PCB1).
3. Replace the Finisher Controller PCB
(PCB1).
4. Replace the DC Controller PCB
(PCB1).
E716-
0000
Error in communication with the
Cassette Module
The communication did not connect
again although the error retry was
executed after failing to
communicate with the Cassette
Module.
1. Check the installation of the Host
Machine and the Cassette Module.
2. Check the connector connection
between the DC Controller PCB (PCB1)
and the Cassette Module Controller
PCB (PCB101).
3. Replace the Cassette Module
Controller PCB (PCB101).
4. Replace the DC Controller PCB
(PCB1).
E719-
0001
Coin vendor error
Error when the coin vendor is
started
- The Coin Vendor, which must
have been connected before the
power was turned OFF, is not
connected when the power is
turned ON
Check cable connection between the
charging management equipment and
the host machine.
While the charging management
equipment is connected for operation,
clear the error in the case of switching to
the operation without the charging
management equipment.
(To prevent a misuse by removing the
charging management equipment, this
error code is displayed.)
E719-
0002
Coin vendor error
IPC error at coin vendor operation
- Open circuit of IPC, unable to
recover the IPC communication
- When open circuit of the
pickup/delivery signal cable is
detected
- Invalid connection is detected
Check cable connection between the
charging management equipment and
the host machine.
While the charging management
equipment is connected for operation,
clear the error in the case of switching to
the operation without the charging
management equipment.
(To prevent a misuse by removing the
charging management equipment, this
error code is displayed.)
E719-
Coin vendor error
Check cable connection between the