29
Code
Description
Remedy
E881-
0001
CPU abnormal
temperature rising
error
Abnormal
temperature of the
1. Send cold air to the device. 2. If there is a shielding
object around the inlet, remove it to secure enough space.
3. Check the fan, and remove dust or replace the fan if it
has an abnormality such as abnormal sound. 4. Replace
the Main Controller PCB.
E822-
0000
Delivery Cooling Fan (Front) (FM3) error
The lock signal was detected for 5.0
seconds while the Delivery Cooling Fan
(Front) (FM3) was being stopped. *The
same status was detected again after
executing an error retry.
1. Check the connector connection
between the Delivery Cooling Fan
(Front) (FM3) and the DC
Controller PCB (PCB1).
2. Replace the Delivery Cooling
Fan (Front) (FM3).
3. Replace the DC Controller PCB
(PCB1).
E822-
0001
Delivery Cooling Fan (Front) (FM3)
rotation error
The lock signal was not detected for 5.0
seconds while the Delivery Cooling Fan
(Front) (FM3) was being driven. *The
same status was detected again after
executing an error retry.
1. Check the connector connection
between the Delivery Cooling Fan
(Front) (FM3) and the DC
Controller PCB (PCB1).
2. Replace the Delivery Cooling
Fan (Front) (FM3).
3. Replace the DC Controller PCB
(PCB1).
E822-
0003
Delivery Cooling Fan (Center) (FM2)
rotation error
The lock signal was not detected for 5.0
seconds while the Delivery Cooling Fan
(Center) (FM2) was being driven. *The
same status was detected again after
executing an error retry.
1. Check the connector connection
between the Delivery Cooling Fan
(Center) (FM2) and the DC
Controller PCB (PCB1).
2. Replace the Delivery Cooling
Fan (Center) (FM2).
3. Replace the DC Controller PCB
(PCB1).
E822-
0005
Delivery Cooling Fan (Rear) (FM1)
rotation error
The lock signal was not detected for 5.0
seconds while the Delivery Cooling Fan
(Rear) (FM1) was being driven.
*The same status was detected again
after executing an error retry.
1. Check the connector connection
between the Delivery Cooling Fan
(Rear) (FM1) and the DC Controller
PCB (PCB1).
2. Replace the Delivery Cooling
Fan (Rear) (FM1).
3. Replace the DC Controller PCB
(PCB1).
E880-
0001
Controller Fan error
Lock of Controller Fan is detected
Check if the connector is
connected
If the connector is OK, replace
Controller Fan.