6
Code
Description
Remedy
E024-
0001
Disconnection of the Developing Assembly
Toner Sensor (TS2)
1. At normal speed: The Developing
Assembly Toner Sensor (TS2) signal was
detected 7500 times in a row at intervals of
100msec.
2. At low speed: The Developing Assembly
Toner Sensor (TS2) signal was detected 4500
times in a row at intervals of 100msec.
* If paper is being fed, the error occurs after
the paper has been delivered.
1. Check the connector
connection between the
Developing Assembly and the
DC Controller PCB (PCB1).
2. Replace the Developing
Assembly.
3. Replace the DC Controller
PCB (PCB1).
E025-
0000
Connector disconnection of the Hopper Toner
Sensor (TS1)
The connection signal of the Hopper Toner
Sensor (TS1) was not detected 10 times in a
row for 100msec.
* If paper is being fed, the error occurs after
the paper has been delivered.
1. Check the connector
connection between the
Hopper Unit and the DC
Controller PCB (PCB1).
2. Replace the Hopper Unit.
3. Replace the DC Controller
PCB (PCB1).
E025-
0001
Bottle Motor (M5) rotation error
The same level of the Bottle Motor (M5) lock
signal was detected 230 times in a row while
detecting the signal every 2.0msec.
* If paper is being fed, the error occurs after
the paper has been delivered.
1. Check the connector
connection between the Bottle
Motor (M5) and the DC
Controller PCB (PCB1).
2. Replace the Bottle Motor
(M5).
3. Replace the DC Controller
PCB (PCB1).
E110-
0001
Laser Scanner Motor rotation error
After startup of the Laser Scanner Motor, the
speed lock signal of the Laser Scanner Motor
was not detected although a specified period
of time had passed.
*When the same status was detected again
after executing an error retry.
1. Check the connector
connection between the Laser
Scanner Unit and the DC
Controller PCB (PCB1).
2. Replace the Laser Scanner
Unit.
3. Replace the DC Controller
PCB (PCB1).
E110-
0002
Laser Scanner Motor rotation error
After the speed lock of the Laser Scanner
Motor settled, the speed lock signal was not
detected 10 times in a row at intervals of
100msec.
*When the same status was detected again
after executing an error retry.
1. Check the connector
connection between the Laser
Scanner Unit and the DC
Controller PCB (PCB1).
2. Replace the Laser Scanner
Unit.
3. Replace the DC Controller
PCB (PCB1