10
PCB.
3. Replace Main Controller PCB
(PCB2).
E315-
0035
Image process device error
MemFill timeout error
1. Turn OFF and then ON the main
power.
2. Check connection of Main Controller
PCB.
3. Replace Main Controller PCB
(PCB2).
E315-
0100
Image process device error
PRIO overrun
1. Turn OFF and then ON the main
power.
2. Check connection of Main Controller
PCB.
3. Replace Main Controller PCB
(PCB2).
E315-
0500
Device timeout
An image synchronous signal from the
Main Controller PCB to the Reader is
not received within 30 seconds.
1. Turn OFF and then ON the main
power.
2. Check the connection of the Main
Controller PCB (including the flat
cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB
(PCB2).
E315-
0501
Device abnormal completion
An abnormal signal from the Main
Controller PCB to the Reader is
detected.
1. Turn OFF and then ON the main
power.
2. Check the connection of the Main
Controller PCB (including the flat
cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB
(PCB2).
E315-
0510
Device timeout
An image synchronous signal from the
Main Controller PCB to the Reader is
not received within 30 seconds.
1. Turn OFF and then ON the main
power.
2. Check the connection of the Main
Controller PCB (including the flat
cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB
(PCB2).
E315-
0511
Device abnormal completion
An abnormal signal from the Main
Controller PCB to the Reader is
detected.
1. Turn OFF and then ON the main
power.
2. Check the connection of the Main
Controller PCB (including the flat