Points to note when installing, removing and cleaning the primary
corona assembly
[Symptom]
E060-0x01 or black lines on image may occur due to deformation of the parts in the primary corona assembly caused by
installation, removal and cleaning of the primary corona assembly.
- E060-0x01 : Primary Charging Wire error (y = 1:Y, 2:M, 3:C, 4:Bk)
[Service work]
Be sure to pay attention to the points noted below when performing the following work.
A) When holding the primary corona assembly with hands
B) When placing the primary corona assembly on a working table
C) When loosening the yellow screws in the slider
D) When removing and installing the shutter
E) When opening and closing the shutter manually 1
F) When opening and closing the shutter manually 2
A) When holding the primary corona assembly with hands
When holding the primary corona assembly with hands, hold it by the handle. (black molded part) When holding the center of the
shield plate as shown in the photo, the shield plate deforms. Using the unit in this state causes a load to the slider [1] around the
center section when the slider [1] moves causing it to stop. As a result, E060-0x01 may occur.
B) When placing the primary corona assembly on a working table
When placing the primary corona assembly on a working table, the leaf spring [1] of the shutter may deform as shown in the
photo [A] if placing the unit with the etching grid plate facing down. The photo [B] is the leaf spring [2] in a normal state. When
the leaf spring deforms, E060-0x01 may occur because it gets stuck to the etching grid plate when the shutter moves.
[Reference] When placing the unit with the etching grid plate [1] facing down, foreign material may attach to the etching grid plate.
When placing the primary corona assembly on a working table, be sure to place it with the etching grid plate facing up.
198
Содержание imagePRESS C10000VPSeries
Страница 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Страница 28: ...4 If the symptom does not improve then check other factors 23 ...
Страница 42: ...3 Output about 10 test prints to verify the effect 37 ...
Страница 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Страница 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Страница 173: ...Model Serial No Document Insertion Folding Unit K1 EU O WGK00631 Document Insertion Folding Unit K1 CN WGL01726 168 ...
Страница 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Страница 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Страница 181: ...176 ...
Страница 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...