[Caution] Changing the value may cause glossiness of image may slightly decrease.
a-3) Output the image having shown the symptom, and check that the symptom does not occur.
If the symptom improvement is inadequate, decrease the setting value of step a-3) down to "-3" by "1" value while observing the
symptom.
a-4) If the symptom does not improve even after setting the parameter in the step a-2) to "-2", then perform the remedy b).
If the symptom does not improve even after performing the remedy a) and the remedy b), then check other causes.
b) Make the leading edge margin broader to improve the symptom.
b-1) Select "Adjust Lead/Tail Margins" and press "Change".
b-2) Press "+" button for Lead Edge, Make sure the setting value [a] is set to "2.0" and press "OK".
The setting range is from "0.0" to "5.0" ("0.0" by default).
Change of the setting value changes the leading edge.
[Caution] Changing this setting may generate trailing edge non-image area.
b-3) Output the image having shown the symptom, and check that the symptom does not occur.
If the symptom improvement is inadequate, decrease the setting value of step b-2) up to "5.0" by "1.0" value while observing the
symptom.
b-4) If the symptom does not improve even after setting the parameter in the step b-2) to "5.0", perform the remedy a).
If the symptom does not improve even after performing the remedy a) and B), then check other causes.
126
Содержание imagePRESS C10000VPSeries
Страница 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Страница 28: ...4 If the symptom does not improve then check other factors 23 ...
Страница 42: ...3 Output about 10 test prints to verify the effect 37 ...
Страница 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Страница 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Страница 173: ...Model Serial No Document Insertion Folding Unit K1 EU O WGK00631 Document Insertion Folding Unit K1 CN WGL01726 168 ...
Страница 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Страница 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Страница 181: ...176 ...
Страница 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...