t-2) Check if there is a disconnected connector for UN401/J6025 and UN102/J1804.
u) For the case that bit4 to bit10 of [PWR- GP10] show "1". (Contact failure of 24VD system is detected.)
u-1) Check if there is a disconnected Relay connector (J7876) between UN401/J6018 to UN102/J1803.
u-2) Check if there is a disconnected connector for UN401/J6018 and UN102/J1803.
v) For the case that bit8 to bit9 of [PWR- GP11] show "1". (Contact failure of 24VE system is detected.)
v-1) Check if there is a disconnected Relay connector (J7875) between UN401/J6019 to UN102/J1802.
v-2) Check if there is a disconnected connector for UN401/J6019 and UN102/J1802.
w) For the case that bit1 to bit5 of [PWR- GP15] show "1". (All 38V errors of Main Station are detected.)
w-1) Check if there is a disconnected connector or a cutoff harness between UN532/J202G to UN401/J6008.
w-2) Replace the UN532 (38V Power Supply PCB A).
x) For the case that bit6 to bit8 of [PWR- GP15] show "1". (All 38V errors of Sub Station are detected.)
x-1) Check if there is a disconnected connector or a cutoff harness for UN402/J6305 to UN201C/J101E, UN201D/J101D.
x-2) Replace the UN533 (38V Power Supply PCB B) and UN534 (38V Power Supply PCB C).
3) Perform same operation which was done when the error occurred to check if the symptom does not occur.
182
Содержание imagePRESS C10000VPSeries
Страница 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Страница 28: ...4 If the symptom does not improve then check other factors 23 ...
Страница 42: ...3 Output about 10 test prints to verify the effect 37 ...
Страница 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Страница 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Страница 173: ...Model Serial No Document Insertion Folding Unit K1 EU O WGK00631 Document Insertion Folding Unit K1 CN WGL01726 168 ...
Страница 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Страница 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Страница 181: ...176 ...
Страница 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...