[Note]Be sure to rotate the drum in the direction of arrows only shown in the following photo.
6) Remove the cleaning unit [1] from the drum unit, and replace the cleaner blade (FC5-8829-000) [2] with a new
one.
[Note]
- Be sure not to damage the edge [a] of a cleaner blade.
- To prevent damage, place the cleaner blade [2] upward.
7) Install the cleaning unit on a drum unit, and install it in a main body.
8) If multiple drum units are to be replaced, conduct procedure 2) to 7) every time before proceeding to next step.
Perform auto gradation adjustment (Full-PASCAL)
Settings/Registration > Adjustment/Maintenance >Adjust Image Quality > Auto Adjust Gradation, then select [Full
Adjustment]
Check the output images made out of Auto Adjust Gradation and confirm that the symptom is not occurring
anymore.
[Service parts]
No.
Part Number
Description
Q'ty
Fig. No.
1
Old
FC5-8829-000
BLADE, CLEANER
1-> 1
710
New
65
Содержание imagePRESS C10000VPSeries
Страница 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Страница 28: ...4 If the symptom does not improve then check other factors 23 ...
Страница 42: ...3 Output about 10 test prints to verify the effect 37 ...
Страница 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Страница 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Страница 173: ...Model Serial No Document Insertion Folding Unit K1 EU O WGK00631 Document Insertion Folding Unit K1 CN WGL01726 168 ...
Страница 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Страница 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Страница 181: ...176 ...
Страница 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...