Measure against failure after system version upgrade (Multi
Function Professional Puncher_A1)
[Symptom/Question]
In the machine earlier than the following countermeasure cut-inserial numbers in factory, the following failures may occur on the
Multi Function Professional Puncher-A1, when the system version upgrade is done for a
main body and an accessory.
- Only LCD light is on, but characters do not appear on an operation panel of Multi Function Professional Puncher-A1.
- E503-0055: Communication Error in the Multi Function Professional Puncher
- E711-0001: IPC communication error (time out error)
[Cause]
For some reason, when power drop or power OFF is caused during the version upgrade process of Multi Function Professional
Puncher-A1, some part of the firmware fails to be written in, causing the above symptom.
[Remedy/Answer]
When the above mentioned failure is observed, replace with the new type MAIN CONTROLLER PCB ASS'Y( FC3-7449-000)[A],
which has its Bootloader firmware modified.
In addition, the Bootloader firmware could not be upgraded by SST, thus the MAIN CONTROLLER PCB ASS'Y is needed tobe
replaced. The new type PCB has Main Ver9.02 or later, and COMM Ver9.05 or later in it.
[NOTE]
The new/old type of MAIN CONTROLLER PCB ASS'Y could be identified by the PART NUMBER [a] [b] printed on a label on a
PCB.
- New type [A]: 7718643[a]
- Old type [B]: 7718575[b]
[Service parts]
No
Part Number
Description
Q'ty
Fig. No.
1
Old
FC3-6944-000
MAIN CONTROLLER PCB ASS'Y
1 - > 0
Q40
New FC3-7449-000
MAIN CONTROLLER PCB ASS'Y
0 - > 1
[Countermeasure cut-in serial numbers in factory]
Model
Serial No.
MFPP-A1 115V
SYM01422
MFPP-A1 230V
SYN00733
231
Содержание imagePRESS C10000VPSeries
Страница 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Страница 28: ...4 If the symptom does not improve then check other factors 23 ...
Страница 42: ...3 Output about 10 test prints to verify the effect 37 ...
Страница 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Страница 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Страница 173: ...Model Serial No Document Insertion Folding Unit K1 EU O WGK00631 Document Insertion Folding Unit K1 CN WGL01726 168 ...
Страница 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Страница 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Страница 181: ...176 ...
Страница 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...