E029-0x01 by the incorrect position of Shutter Solenoid or error
of shutter slide lever
[Symptom]
When installing or operating, E029-0x01 may occur on the following serial numbers affected.
- E029-0x01 : Home position error of the drum patch sensor shutter (x) was detected. (x:1/2/3/4=Y/M/C/ Bk )
[Cause]
The following three four causes results in the above-mentioned symptom.
a). Incorrect position of the shutter solenoid
When the shutter solenoid is attached in the process, the shutter [1] of patch sensor should have been attached in the state of
fully opened [B]. However it has not been attached with proper adjustment. Photo [A] shows the state that the shutter [a] is not
opened fully and Photo [B] shows the proper state.
<Serial number affected>
iPR C10000VP series US : from WBC00500 to WBC00515
iPR C10000VP series EU / O : only WEJ00500
b). Error of the shutter slide lever
The slide lever and the shutter cover [2] interfere with each other [a], and the shutter may not be able to be opened or closed.
<Serial number affected>
iPR C10000VP series US : from WBC00500 to WBC00541, from WBC10001 to WBC10054,WBC10056, WBC10058 and
WBC10059
iPR C10000VP series EU / O : from WEJ00500 to WEJ00533, from WEJ10001 to WEJ10018
iPR C10000VP series JP : from WEK10001 to WEK10013
c). Operational error of the shutter
If Jam or error occurs during printing, the developing bias suddenly stops the output. At this time, the carrier absorbed to the drum
surface floats and may enter inside the drum patch sensor. In particular, the machine in which jams and errors frequently occur
during printing, the carrier enters more possibly, and the operational error may rarely occur.
Therefore, a measure is taken so that the shutter moves smoothly by applying Hanarl to the hatched areas of the slide lever [1],
the shutter slider [2] and the shutter [3], even if the carrier enters inside the drum patch sensor.
183
Содержание imagePRESS C10000VPSeries
Страница 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Страница 28: ...4 If the symptom does not improve then check other factors 23 ...
Страница 42: ...3 Output about 10 test prints to verify the effect 37 ...
Страница 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Страница 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Страница 173: ...Model Serial No Document Insertion Folding Unit K1 EU O WGK00631 Document Insertion Folding Unit K1 CN WGL01726 168 ...
Страница 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Страница 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Страница 181: ...176 ...
Страница 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...