[Remedy/Answer]
If the above symptom occurs, follow the procedures below:
1) Referring to Service Manual, replace the 4 parts, listed below of the primary corona assembly of the color that causes the poor
image density, at the same time.
- ETCHING GRID PLATE: FC0-9857
- 0.06MM CORONA WIRE 0.06MM (20M): FB4-3687
- WIRE CLEANING PAD HOLDER: FL2-0464
- WIRE CLEANING PAD BLOCK: FL2-4271
2) Referring to Service Manual, check the filter base (FC6-8137-000) inside the exhaust duct unit ozone filter for clogging.
If the old-type filter base (FC6-8137-000) [A] is clogged just like [1] mentioned above, replace it with the new-type filter base
(FC6-8137-010) [B]. The Fig. [A] shows the old type and the figure [B] shows the new type.
3) Execute User Mode, Settings/Registration>Adjustment/Maintenance>Maintenance>Wire cleaning.
4) Print the sample image to check that poor image density does not occur.
[Note]
Clean or replace each filter [1] to [9] listed in the following table of the filters by referring to its respective estimated cleaning timing
and estimated life (sheets) per replacement.
If the filters with * are clogged, the above-mentioned symptom is likely to occur.
Especially, if the filter base is clogged, the above-mentioned symptom is more likely to occur. The estimated cleaning timing for
the filter base is every 2.000.000 sheets. This is the same timing as the estimated life (sheets) per replacement for the exhaust
duct unit ozone filter, so when replacing it, clean the filter base.
<Table of filter>
№
Location
Name
Part number
Estimated clean-
ing timing
Estimated life (sheets)
per replacement
[1]
Main Station
Upper Left Suction Filter
FC9-5783
-
1,000,000
[2]
※
Main Station
Rear Ozone Filter (M/C/Bk)
FC7-4563
-
2,000,000
[3]
※
Main Station
Rear Ozone Filter (Y)
FC9-6014
-
2,000,000
[4]
※
Main Station
Rear Toner Filter
FB2-4383
-
500,000
[5]
※
Main Station
Upper Right Suction Filter
FC9-6046
-
1,000,000
[6]
Sub Station
Rear Middle Ozone Filter
FC6-2035
500,000
2,000,000
[7]
Sub Station
Exhaust Duct Unit Ozone Filter
FC6-2035
500,000
2,000,000
[8]
※
Sub Station
Filter base
FC6-8137
2,000,000
-
[9]
Power Unit Sta-
tion
Ozone Filter
FC6-3483
-
2,000,000
[Service parts]
84
Содержание imagePRESS C10000VPSeries
Страница 1: ...Troubleshooting Guide imagePRESS C10000VPSeries July 16 2019 Canon U S A Inc ...
Страница 28: ...4 If the symptom does not improve then check other factors 23 ...
Страница 42: ...3 Output about 10 test prints to verify the effect 37 ...
Страница 142: ...Model Serial number PAPER DECK UNIT_ F1 A4 WES05369 137 ...
Страница 164: ...4 5 Make some prints and check that the above issue does not occur 159 ...
Страница 173: ...Model Serial No Document Insertion Folding Unit K1 EU O WGK00631 Document Insertion Folding Unit K1 CN WGL01726 168 ...
Страница 179: ...C 2 24VB system C 3 24VC system C 4 24VD system C 5 24VE system 174 ...
Страница 180: ...C 6 24VF system C 7 24VH system C 8 24VI system C 9 24VJ system 175 ...
Страница 181: ...176 ...
Страница 261: ... Service parts CABLE MOTOR CONNECTING FM1 T808 256 ...