
Chapter 5
5-29
F-5-22
T-5-31
Conditions for a Call
The function is enabled when ACTIVATION is set to ON, and the number of prints and the date currently registered will server as its starting point.
Condition 1: When as many prints as set for PAGES under CRITERION have been made.
Condition 2: When the cartridge runs out of toner, requiring replacement.
Condition 3: When as many days as set for DAYS under CRITERION have been made.
Condition 4: When a service error related to the printer has occurred.
A log on the following is used for the execution of this function:
- Total number of prints made by the printer.
- Number of prints that previously satisfied condition 1.
- Date/Number of prints that previously satisfied condition 3.
Memo
Executing ALL CLEAR or CLEAR for Remote CRG will also clear the log data.
Condition 1:
When the difference between the number of prints and the one which satisfies the previous condition 1 reaches the number of prints specified in PAGES of CRI-
TERION, create a BFT file and go on to the transmission operation.
If the number of print in PAGES of CRITERION is set to '0,' notice in accordance with this condition is not made.
Condition 2:
When the cartridge runs out of toner to require replacement, a call will be made.
Thereafter, no call will be made under condition 2 until the cartridge has been replaced and the power has been turned off and then on.
However, if condition 2 occurs once again when the power is turned on after replacement of the cartridge, a call will be made.
Condition 3:
When as many days as set pass since the day on which condition 3 is satisfied and, in addition, when 12 hours pass since the time at which ACTIVATION is set to
ON, a call will be made.
Condition 4:
When a service error that is related to the printer occurs, call will be made.
Thereafter, no call will be made under condition 4 unless the error has been cleared and the power has been turned off and then on once again.
However, if condition 4 occurs when the power is turned on once again after clearing of the error, a call will be made.
Memo
If a connection to the target machine fails when transmitting a BFT file, a shift will be made to redialing mode. Redialing may be enabled/disabled, and the
number of redialing sessions depends on user settings.
BFT File
A BFT file is constructed as follows:
ACTIVATION:
Use it to ON/OFF the function
PRODUCT NUMBER:
Use it to register a product number (10 characters; upper case, lower case;
numerals; symbols).
SERIAL NUMBER:
Use it to register a serial number (8 characters; upper case, lower case; numerals;
symbols).
CUSTOMER NUMBER:
Use it to register a serial number (8 characters; upper case, lower case; numerals;
symbols).
SERVER PHONE NBR:
Use it to register the telephone number of the contact (25 characters; numerals;
tone; pause; space).
CRITERION:
Use it to store information about the cause of a call.
PAGES: number of print 3500 (0-9999)
DAYS: number of days passed 30 (0-9999)
REPORT:
Use it to generate a report of BFT registration data issued.
MANUAL TX:
Use it to manually transmit BFT registration data.
CLEAR:
Use it to clear all parameters set under Remote CRG.
#17 Remote CRG
ACTIVATION
PRODUCT NUMBER
SERIAL NUMBER
CUSTOMER NUMBER
SERVER PHONE NBR
CRITERION
REPORT
CLEAR
MANUAL TX
Содержание FAX-L380S Series
Страница 1: ...Jan 19 2006 Service Manual FAX L380S Series ...
Страница 2: ......
Страница 6: ......
Страница 14: ...Contents ...
Страница 15: ...Chapter 1 PRODUCT DESCRIPTION ...
Страница 16: ......
Страница 18: ......
Страница 30: ......
Страница 31: ...Chapter 2 TECHNICAL REFERENCE ...
Страница 32: ......
Страница 34: ......
Страница 44: ......
Страница 45: ...Chapter 3 DISASSEMBLY AND ASSEMBLY ...
Страница 46: ......
Страница 52: ......
Страница 111: ...Chapter 4 MAINTENANCE AND INSPECTION ...
Страница 112: ......
Страница 114: ......
Страница 127: ...Chapter 5 TROUBLESHOOTING ...
Страница 128: ......
Страница 167: ...Chapter 6 APPENDIX ...
Страница 168: ......
Страница 170: ......
Страница 175: ...Jan 19 2006 ...
Страница 176: ......