Trap Messages
3-19
Configuring the Trap Table
Alloc Error on Master SNMP Agent
494
A buffer could not be allocated to process an SNMP message.
Severity
Critical (Level 1)
BPAD: Invalid Q Pkt “n”—PL
500
An invalid Q packet has been received, disabling the port.
Severity
Minor (Level 3)
Action
ConÞgure the LIC or remove it from the node.
BPAD: Invalid Pkt “n”—PL
501
An invalid packet has been received, disabling the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
BPAD: Invalid MSG “n”—Link
502
An invalid message has been received, disabling the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
BPAD: Invalid MSG “n”—Exchange
503
An invalid message has been received, disabling the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
BPAD: Invalid CUA “n” DUA “n”
504
An invalid message has been received, disabling the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
LINK: Invalid MSG fc “n”—BPAD
505
An invalid message has been received, disabling the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
BSCI: Invalid control block
513
An error has occurred and has disabled the port.
Severity
Minor (Level 3)
Action
Take the same action as for message 500.
Содержание SPECTRUM FRX6000
Страница 1: ...Title Page Portable Management Application for the FRX4000 FRX6000 and SmartSwitch 1800 User s Guide ...
Страница 2: ......
Страница 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status ...
Страница 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status ...
Страница 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices ...
Страница 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics ...