Monitoring Hub Performance
2-15
Using the FRX4000, FRX6000, and SmartSwitch 1800 Hub View
Connector Type
This port display form indicates the connector type supported by the selected
port. This value (from the OID
nlIfConnectorType
) is determined by a combination
of cable and physical port type, as follows:
rs232
Indicates an RS232 serial port, which must always use an
RS232 cable.
v35
Indicates a v.35 serial port, which must always use a v.35
cable.
rs449
Indicates an RS422 serial port conÞgured for an RS449
cable.
rs530
Indicates an RS422 serial port conÞgured for an RS530
cable.
x21
Indicates an RS422 serial port conÞgured for an X21
cable.
csudsu (csu/dsu)
Indicates a CSU/DSU interface.
none
This value displays for LAN ports.
voice
This value displays for voice channels.
Speed
Indicates the speed conÞgured for the selected port, as reported by the MIB II OID
ifSpeed
. The speed conÞgured for a port must match the speed of the line which
will be connected to that interface, and the speed conÞgured for the port at the
other end of the connection.
Max Packet Size
Displays the size of largest datagram which can be sent or received on this port, in
octets (as reported by the MIB II OID
ifMtu
). This value is speciÞc to the protocol
running on the selected interface.
IF Index
Displays the MIB II
ifIndex
value assigned to each port. Note that the displayed
index values do not necessarily increment as you might expect Ñ as the FRX or
SmartSwitch 1800 device boots, each physical or
logical
port which is detected will
be incrementally assigned an index value, which may result in gaps between the
index values assigned to the physical ports displayed in the Hub View. Note that
the assigned ifIndex values are constant between bootups; however, once the
device reboots, the same ifIndex values will not necessarily be assigned to the
same physical or logical ports (if the deviceÕs conÞguration has changed).
TIP
To map logical ports to their physical port locations, use the OID
nlIfPhyPort
.
Содержание SPECTRUM FRX6000
Страница 1: ...Title Page Portable Management Application for the FRX4000 FRX6000 and SmartSwitch 1800 User s Guide ...
Страница 2: ......
Страница 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status ...
Страница 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status ...
Страница 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices ...
Страница 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics ...