Configuring the Trap Table
3-26
Trap Messages
SDLC Rem. Link Stn Not Responding
701
Self-explanatory. (
Rem Link Stn
is the Remote Link Station.)
Severity
Major (Level 2)
Action
Check the PU to make sure it is operational.
SDLC Link Stn Sent DM
702
The link station sent a Disconnect Mode response, and the logical link is down.
Severity
Major (Level 2)
SDLC Link Stn rcvd FRMR, Inv. cmd
704
The remote device received an invalid command and responded with a Frame
Reject.
Severity
Major (Level 2)
SDLC Stn rcvd FRMR, IFLD invalid
705
The remote device received an unpermitted I frame and responded with a Frame
Reject.
Severity
Major (Level 2)
SDLC Stn rcvd FRMR, Nr invalid
706
The remote device received a frame with an invalid N
(r)
and responded with a
Frame Reject.
Severity
Major (Level 2)
SDLC Stn rcvd FRMR, Ifld too long
707
The remote device received an I frame that was too long and responded with a
Frame Reject.
Severity
Major (Level 2)
SDLC Rem Stn sent Invalid Command
708
The remote device received an invalid or unsupported command.
Severity
Major (Level 2)
SDLC Rem Stn sent unexpected IFLD
709
The remote device send an unpermitted I frame.
Severity
Major (Level 2)
SDLC Rem Stn sent invalid Nr
710
The remote device sent a frame with an invalid N
(r)
.
Severity
Major (Level 2)
Содержание SPECTRUM FRX6000
Страница 1: ...Title Page Portable Management Application for the FRX4000 FRX6000 and SmartSwitch 1800 User s Guide ...
Страница 2: ......
Страница 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status ...
Страница 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status ...
Страница 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices ...
Страница 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics ...