Trap Messages
3-27
Configuring the Trap Table
SDLC Rem Stn Exceeded window size
711
The number of frames sent by the remote device has exceeded the window size.
Severity
Major (Level 2)
SDLC Station Inactivity time exp
712
The timer deÞned by the parameters
No Response Poll Period
and
Maximum
Retransmissions
in the SNA Port record has expired.
Severity
Major (Level 2)
Action
Check the PU to make sure it is operational.
SDLC XID Retries exhausted
713
The retry limit for XID has been exceeded and link establishment has failed.
Severity
Major (Level 2)
SDLC Rem Stn sent FRMR—no reason
714
The remote station sent a Frame Reject with no reason.
Severity
Major (Level 2)
SDLC Remote RNR limit exceeded
715
The remote station is busy. This could be a hardware or buffer problem in the
remote device.
Severity
Major (Level 2)
Action
Check the hardware and conÞguration at the remote device.
SDLC Rem Tx Frame exceeds MAXDATA
717
A frame transmitted by the remote station exceeds the conÞgured value for
Maximum Bytes per Frame.
Severity
Major (Level 2)
SDLC Rem sent UA in NRM
718
The remote station sent a UA while in Normal Response Mode, which is not
allowed.
Severity
Major (Level 2)
SDLC No DSR on link
720
A necessary DSR was not received from the DCE.
Severity
Major (Level 2)
Action
Check the modem to make sure it is operational.
Содержание SPECTRUM FRX6000
Страница 1: ...Title Page Portable Management Application for the FRX4000 FRX6000 and SmartSwitch 1800 User s Guide ...
Страница 2: ......
Страница 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status ...
Страница 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status ...
Страница 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices ...
Страница 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics ...