Trap Messages
3-9
Configuring the Trap Table
Link Disabled
401
The port has been disabled from the On-Line Port Operations menu.
Severity
Major (Level 2)
Link Disconnected
402
For X.25, this means that the link is disconnected and level 2 cannot be
established.
For SNA TPAD, this means that an XID command frame has been issued by the
TPAD, but either there has been no response or the received XID data does not
match the XID data conÞgured for the TPAD subscriber.
For SNA HPAD, this means that no XID or SNRM command frame has been
received for any link address conÞgured for the HPAD subscriber.
Severity
Major (Level 2)
Action
Check the hardware at both ends to make sure the devices are
operational and cables are securely connected. For SNA, also
check the conÞguration records to make sure they match the
HPAD/TPAD.
Link Up
403
The level 2 link is up.
Severity
Major (Level 2)
X.25 Link Failed
404
The link has failed; some modem controls are not present, and the physical link is
down.
Severity
Major (Level 2)
Action
Check the modem and cables for secure connections and proper
operation.
Restart with cc “n” dc “n”
405
A Restart has been issued, with the cause code
(cc)
and diagnostic code
(dc)
shown.
Severity
Informational (Level 4)
Action
Depends on the cause. If necessary, contact your service
representative.
Содержание SPECTRUM FRX6000
Страница 1: ...Title Page Portable Management Application for the FRX4000 FRX6000 and SmartSwitch 1800 User s Guide ...
Страница 2: ......
Страница 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status ...
Страница 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status ...
Страница 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices ...
Страница 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics ...