Configuring the Trap Table
3-8
Trap Messages
Trn Port Usage exceeded T: “n” C: “n”
319
The port statistic
% Transmit Port Utilization
has exceeded the threshold
(T: ÒnÓ)
that was set by the user. (
C: ÒnÓ
is the current value.)
Severity
Informational (Level 4)
Action
If this happens frequently, you may need to add ports or reroute
some trafÞc.
Receive Yellow Alarm Condition Set
338
A Yellow Alarm was received.
Severity
Major (Level 2)
Action
Contact your T1 carrier.
Receive Yellow Alarm Condition Set
339
The condition that caused event 338 has been cleared
Severity
Informational (Level 4)
LIC “n” Installed, Not Configured
377
The speciÞed Line Interface Card (LIC) exists in the node, but has not been
conÞgured in the Line Processor Þle.
Severity
Minor (Level 3)
Action
ConÞgure the LIC or remove it from the node.
LIC “n” Configured, Not Installed
378
The speciÞed Line Interface Card (LIC) has been conÞgured in the Line Processor
Þle, but does not exist in the node.
Severity
Critical (Level 1)
Action
Install the LIC or delete its record.
LIC “n” Config Mismatch—Type “n”
379
The interface type of the speciÞed Line Interface Card (LIC) installed in the node
is different from the interface type conÞgured in the Line Processor Þle. As a
result, the software does not load properly and will not operate.
Severity
Major (Level 2)
Action
Change either the card or the Þle.
Link Enabled
400
The port has been enabled from the On-Line Port Operations menu.
Severity
Major (Level 2)
Содержание SPECTRUM FRX6000
Страница 1: ...Title Page Portable Management Application for the FRX4000 FRX6000 and SmartSwitch 1800 User s Guide ...
Страница 2: ......
Страница 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status ...
Страница 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status ...
Страница 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices ...
Страница 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics ...