BSCI Subscriber ID Information
The top part of the window displays a list of BSCI port subscribers. The bottom
part of the window allows you to modify or add the following BSCI subscriber
information:
Local Subscriber ID
This is the subscriber address of the local end of a BSCI connection. Enter a
Subscriber ID of up to 15 digits. This is the same subscriber ID that is speciÞed in
the Subscriber Table (see Chapter 4,
ConÞguring the Subscriber Table
, for
Subscriber ID conventions). Each Local Subscriber conÞgured here must also be
conÞgured in the Subscriber Table, so that routing information for each subscriber
address can be speciÞed.
Remote Subscriber ID
This is the subscriber address of the remote end of a BSCI connection. It is used by
the local device to identify where a call is going. Enter a Subscriber ID of up to 15
digits. A Subscriber ID record must also be conÞgured for this address (see
Chapter 4,
ConÞguring the Subscriber Table
for Subscriber ID conventions).
If the BSCI port is one end of a connection to a logical port in the FRX or
SmartSwitch 1800, this ID must match a Subscriber ID conÞgured for the logical
port.
Connection ID
This number identiÞes the association between a local subscriber and a device
conÞgured in the BSCI Device Information window (see
ConÞguring BSCI
Devices
,
page 8-9
).
Auto Call
This parameter is relevant only if the
PAD Type
speciÞed for this port is TPAD. If
Yes
is selected, a TPAD will automatically call its HPAD when the Control Unit
(CU), identiÞed by the Control Unit ID in the BSCI Device Information window
(see
ConÞguring BSCI Devices
,
page 8-9
) becomes active. If
No
is selected, no
automatic call is placed. If the TPAD is connecting to a logical port in the FRX or
SmartSwitch 1800,
Auto Call
must be set to
Yes
. The default value for this
parameter is
No
.
Retry Timer
The amount of time (in seconds) between
Auto Call
retries (see above). If Auto
Call is disabled, (if
No
was selected), this Þeld will be grayed out. The default
value for this parameter is 60.
Retry Count
The maximum number of times an
Auto Call
(see above) will be sent. If Auto Call
is disabled, (if
No
was selected), this Þeld will be grayed out. The default value
for this parameter is 0 (indeÞnite).
Содержание SPECTRUM FRX6000
Страница 1: ...Title Page Portable Management Application for the FRX4000 FRX6000 and SmartSwitch 1800 User s Guide ...
Страница 2: ......
Страница 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status ...
Страница 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status ...
Страница 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices ...
Страница 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics ...