4-8
FRX/FRM 3. 3 User G uide, Rev 04
Figure 4-5 LP Configuration Menu for FRX6000
[A],[B],[B]
from Main Menu
On a new record for an RLP that is not installed,
Status
and
Memory Con-
figuration
will be blank until the record is saved.
Although nine protocol entries are shown, a 4MB RLP supports a
maximum of five.
To add or remove a protocol:
1. Press the letter corresponding to the protocol number. The protocol in the
Configured
column will change to the next one in the list shown in Table 4-3 on
page 4-9.
2. Reboot the node as follows:
Rebooting will clear all connections on this node. However, the
node must be rebooted to implement the change.
a. Press
[F10]
.
b. When asked:
Reboot the Node?
, press
[Y]
.
c. Type
restart [Enter]
.
Nod e Name=nod exyz
Line Process or Con figu ration
*
LP:
1
*
S tatus:
I nstalled
*
Memory Configuration:
8 Meg
A LP Typ e:
R LP
B Line I nterface C ard 1:
V.35
C Line I nterface C ard 2:
RS -232
C onfigured
Loaded
D Protocol 1:
X .25
X.25
E Protocol 2:
FRL
FR L
F Protocol 3:
A sync
Asyn c
G Protocol 4:
S DLC
SDLC
H Protocol 5:
I P
IP
I
Protocol 6:
N one
J
Protocol 7:
N one
K Protocol 8:
N one
L Protocol 9:
N one
Option:
Содержание MMAC-Plus 9F116-01
Страница 2: ......
Страница 15: ...Section I Introduction ...
Страница 16: ......
Страница 37: ...Section II Configuration ...
Страница 38: ......
Страница 46: ......
Страница 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Страница 174: ......
Страница 196: ......
Страница 271: ...Section III Operation ...
Страница 272: ......
Страница 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Страница 370: ......
Страница 371: ...Section IV Appendices ...
Страница 372: ......
Страница 383: ...Appendix D Cause and Diagnostic Codes ...
Страница 394: ......
Страница 398: ......
Страница 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...