9-8
FRX/FRM 3. 3 User G uide, Rev 04
mented. The timer will be de-activated on reception of any valid frame from the line
during
Link Down
.
No Response Retry Count
specifies how many times the user device will be polled (if it is not responding) before
control is passed on the next cluster (accompanied by other condition checks).
Error Retransmit Count
specifies the number of times the node will resend a block of data after the receiving
device has detected an error in that block.
NAK Retry Count
specifies the number of times the node will send a frame when the receiving device is
unable to acknowledge; that is, returns a NAK to the node.
Block Check
used only when
EBCDIC
is
N
, sets the redundancy check parameter:
A
= crc16 (crc = Cyclic Redundancy Check)
B
= even lrc (lrc = Logical Redundancy Check)
C
= odd lrc
Data Mode
used only when
EBCDIC
is
N
, sets the parity parameter:
A
= 7 bit odd
B
= 7 bit even
C
= 8 bit no parity
Subscriber Parameters
Sq (Sequence)
is simply a line number to ease selection of a line on the screen to change. To move to
another line, press
[A]
and enter the sequence number.
Local Sub
is the ID (subscriber address) of the local end of a BSC connection. (A Subscriber
record must also be configured for this subscriber ID.)
Remote Sub
is the ID (subscriber address) of the remote end of a BSC connection. (A Subscriber
record must also be configured for this subscriber ID.)
Autocall
causes a BSC TPAD to automatically call its HPAD when the controller (identified by
Link Address) becomes active. This parameter has no function if the port is an HPAD.
Retry Timer
is the time between autocall retries.
Retry Number
is the maximum number of times an autocall will be sent.
Connection ID
is an internal identifier that will link the BSC port with a device configured in the BSC
Devices file (described on page 9-19).
Содержание MMAC-Plus 9F116-01
Страница 2: ......
Страница 15: ...Section I Introduction ...
Страница 16: ......
Страница 37: ...Section II Configuration ...
Страница 38: ......
Страница 46: ......
Страница 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Страница 174: ......
Страница 196: ......
Страница 271: ...Section III Operation ...
Страница 272: ......
Страница 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Страница 370: ......
Страница 371: ...Section IV Appendices ...
Страница 372: ......
Страница 383: ...Appendix D Cause and Diagnostic Codes ...
Страница 394: ......
Страница 398: ......
Страница 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...