Port
is the physical port on which the backup DLCI is being configured.
DLCI
is the backup being configured.
WaitTimer
is the time after a primary DLCI failure that the software will wait for this DLCI to
become active before checking the next backup DLCI. If the backup does not become
active before the timer expires, the software will search the backup group for the next
available backup.
ProtEnab
enables (if
Y
) the backup protocol on the specified DLCI. It should be set to
Y
if (and
only if) the remote device is an FRX/FRM with the backup protocol enabled on the
remote DLCI connected to this backup group entry.
The remote node must be the same one to which the primary DLCI was connected,
and the remote node's backup DLCI must be on the same RLP as its primary DLCI.
Also, the primary DLCI in the initiating node must have the remote node's primary
RLP/port/DLCI configured in its DLCI parameters.