Configuring Node Parameters
3-5
Node Defaults Parameters
All possible parameters on the first two Node Defaults screens are listed in Table 3-2,
and the NetView parameters on the third screen are listed in Table 3-3 (on page 3-9).
Descriptions of most parameters follow each table.
Depending on the values configured for some parameters, other parameters might not
be displayed.
1
Remember that the software sees uppercase as different from lowercase.
2
Can be:
◆
a 1–15 digit number (address).
◆
(FRX6000/FRM only) a COM port:
C1
or
C2
, plus
C3
or
C4
if the device contains those
ports.
◆
(FRX6000/FRM only) a parallel (LPT) port:
P1, P2, P3.
3
A value of
0
means that no status will be sent.
4
If
0
, the connection will remain active continuously.
5
Continuous retries until connection is established.
6 Note that the parameter
On-Line Temporary Changes
appears on all three screens;
changing this parameter on one screen will automatically change it on the others.
Table 3-2 Node Defaults Parameters
Parameter
Valid Values
Default Value
Node Name
up to 8 characters
none
Remote Control ID
0–15 digits
none
Remote Control Pwd
0–15 characters
1
remote
Fi le Transfer ID
0–15 digits
none
Fi le Transfer Pw d
0–15 characters
1
ftran
Coll ecting Node ID
0–15 digits
none
Coll ecting Node Pwd
0–15 characters
1
al arms
Primary Al arm O utput ID
see footnote
2
none
Primary Al arm O utput Pwd
0–15 characters
1
al arms
Secondary Al arm Output ID
see footnote
2
none
Secondary Al arm Output Pw d
0–15 characters
1
al arms
Com. Port Thruput
A–H
H
(9600 bps)
Com. Port Pari ty
0, 1, 3
0
(none)
Com. Port Stopbi t
1, 2
1
Bi ts Per Character
7, 8
8
Coll ecting Node
Y/ N
N
Max Congesti on
1–50
(%)
50
Min Congestion
1–50
(%)
25
Periodic Status Timer
0–30
(min)
3
1
Li ne Idl e Timer
0–65535
(sec)
0
4
Al arm Autocall Timer
5–3600
(sec)
60
Al arm Max Retries
0–99
0
(no max)
5
On-Line Temporary Changes
Y/ N
Y
Содержание MMAC-Plus 9F116-01
Страница 2: ......
Страница 15: ...Section I Introduction ...
Страница 16: ......
Страница 37: ...Section II Configuration ...
Страница 38: ......
Страница 46: ......
Страница 76: ...4 18 FRX FRM 3 3 User Guide Rev 04 ...
Страница 174: ......
Страница 196: ......
Страница 271: ...Section III Operation ...
Страница 272: ......
Страница 340: ...17 46 FRX FRM 3 3 User Guide Rev 04 ...
Страница 370: ......
Страница 371: ...Section IV Appendices ...
Страница 372: ......
Страница 383: ...Appendix D Cause and Diagnostic Codes ...
Страница 394: ......
Страница 398: ......
Страница 402: ...G 4 FRX FRM 3 3 User Guide Rev 04 ...