List of default parameters in the automatic menu:
To reset the gluing and cover clamp parameters to their "AUTO" values, press the
icon in the automatic menu.
• Binding parameters: - Carriage speed: fast.
- Milling activated.
- Milling depth: 1 mm.
- Glue cut-off on front: 5 mm.
- Glue cut-off on back: 5 mm.
- Thickness of glue film: adapted to the thickness of the book
(0,5mm by default).
• Cover clamp parameters: - Cover mode activated.
- N->FIRST mode activated.
- 4 creases are selected: creases on the spine of the book
and courtesy creases.
- No folding wings.
- 6 mm between the courtesy crease and the crease on the
book's spine.
- Height of cover on the front of the book = height of book.
- Output mode: "Free".
- Cover suction level: Adaptation to the cover to be picked up.
- Glue drying time before nipping: adapted to the thickness of
the book.
- Glue drying time during nipping: adapted to the thickness of
the book.
- Adjustment of pressure on spine: adapted to the thickness of
the book.
- Adjustment of lateral pressure: adapted to the thickness of
the book.
• Miscellaneous settings: - Unit counter mode.
- Vibration activated with the amplitude in the central position.
Note: These parameters may be modified by a qualified technician according to the
customer's requirements.
Содержание BB3002 PUR
Страница 7: ...Operator Manual Page 7 Initial issue 05 08 Latest revision 11 08 Environmental compliance 141...
Страница 9: ...Operator Manual BB3002 Page 9 Initial issue 05 08 Latest revision 11 08 BB3002...
Страница 82: ...Operator Manual BB3002 Page 82 Initial issue 05 08 Latest revision 11 08 5 4 Not available...
Страница 103: ...Operator Manual BBL Page 103 Initial issue 09 13 Latest revision BBL...
Страница 120: ...Operator Manual BBC Page 120 Initial issue 09 13 Latest revision BBC...