Operator Manual
BB3002 Page 74
Initial issue: 05/08
Latest revision: 11/08
4.12.2 Opening/closing the cover clamps:
These two buttons open and close the cover clamps.
This is useful for cleaning, removing films of glue from the non-stick cover clamp
plate.
Note: As a safety measure, clean the plate with the interlock open.
4.12.3 Restarting the graphical interface, the PLC and communication between them:
In the event of problems, it is possible to:
• Restart the touch-screen (UI).
To completely reinitialize the UI software.
• Restart the binder's computer (PLC).
To completely reinitialize the binder software.
WaRnInG:
A power OFF/ON does not reinitialize the software.
• Restart communications between the screen and the PLC.
Note: If the error continues, check the connection from the UI's serial port to the PLC.
4.12.4 Thickness value of the last booklet bound:
At anytime, the operator can also know the thickness value of the last booklet bound.
This can be used in application like “doctor booklet” in which the thickness should
be entered for the second wing length.