6-5
Starting up Recovery Console
You can start up Recovery Console in two ways:
Start up Recovery Console installed on the system.
Start up Recovery Console from the Windows Server 2003 CD-ROM.
Installing Recovery Console on the system
1.
Start up the Fault Tolerant Server series and log on to Windows Server 2003.
2.
Insert the Windows Server 2003 CD-ROM into the drive.
3.
From [Start] of the taskbar, select [Run...] to run.
For Windows Server 2003 R2, Enterprise Edition:
Optical disk drive:\i386\winnt32.exe /cmdcons /syspart:c: /tempdrive:c:
For Windows Server 2003 R2, Enterprise x64 Edition:
Optical disk drive:\amd64\winnt32.exe /cmdcons /syspart:c: /tempdrive:c:
4.
Follow the messages that appear on the screen to continue.
Starting up the Recovery Console
1.
Disable the configuration for OS Boot Monitoring function.
Select [Server] - [Monitoring Configuration] - [OS Boot Monitoring] and choose “Disabled.”
See “Step 3: Disable OS Boot Monitoring Function” (page 4-9) for details.
2.
If you have duplexed the HDDs with the RDR (Rapid Disk Resync) feature, unmount and remove
CPU/IO module 1 before starting up the Recovery Console. If the disk error of the slot 1 of the CPU/IO
module 1 is apparent, unmount and remove the CPU/IO module 0.
Note that if you execute the Recovery Console with two CPU/IO module mounted and implemented, there
may occur the OS stop error on the startup after the Recovery Console is used.
Mount the removed CPU/IO module after using the Recovery Console and normal OS startup.
<When starting up Recovery Console installed on the system>
(a)
Select Microsoft Windows Recovery Console in “Please select the operating system to start:”
(b)
When the following message appears on the screen press
F6
quickly.
Please select the operating system to start:
Windows Server 2003, Enterprise
Microsoft Windows Recovery Console
Содержание NovaScale R630 E1
Страница 1: ...NovaScale R630 E1 Setup Guide NOVASCALE REFERENCE 86 A1 43FA 00...
Страница 2: ......
Страница 14: ...xiv This page is intentionally left blank...
Страница 24: ...1 10 This page is intentionally left blank...
Страница 28: ...2 4 This page is intentionally left blank...
Страница 40: ...3 12 9 Fasten the levers on the left and right sides with screws 10 Mount the CPU IO module 1 in the same way...
Страница 50: ...3 22 This page is intentionally left blank...
Страница 104: ...4 54 6 Click the Advanced tab on the Performance Options window 7 Click Change in the Virtual memory box...
Страница 110: ...4 60 This page is intentionally left blank...
Страница 142: ...6 18 This page is intentionally left blank...
Страница 145: ......
Страница 146: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 43FA 00...