15 Appendix
15.1 Operating messages
z
Press the "Service"
e
button a number of times to switch
between the various status displays.
* “- H” May also appear when the boiler is in frost protection mode. There has been a continuous DHW demand and CH request for more then one hour.
The boiler then switches to CH mode. The operating code flashing in the display after the service button is pressed is A01/ 818.
To enable the DHW, restart the boiler.
Display
Meaning
Normal mode
[-/h/\|
Boiler in space heating mode *
[=/h/\|
Boiler in DHW heating mode
Normal mode
[0/a/\|
Burner interval circuit, burner will start automatically after 10 minutes
[0/c/\|
Burner is started
[0/e/\|
More capacity was delivered than required
[0/h.\|
Standby
[0/l/\|
Gas burner fitting is opened
[0/u/\|
Initializing/ pre purge
[0/y/\|
Flow temperature higher than set
Test mode
Boiler in flue gas test
Manual mode
Boiler in manual mode
Reset
[r/e/\|
Reset
(after holding the "Reset"
c
button for 5 seconds, the heating system is returned to its
switch-on condition)
Table 13 Normal operating messages
=/-
0
-
Dot displayed in right-
hand bottom corner
[-/a.\|
-
Blinking dot in right-
hand bottom corner
[-/h.}