Switch off the heating system using the main switch.
z
Dismantle the boiler again and flush the heat exchanger
with water.
z
Pull the condensate trap from the condensate plate
(fig. 48, pos. 1).
z
Loosen the condensate trap from the connection (fig. 48,
pos. 2) and remove it.
z
Use a bristle brush to clean the condensate trap.
z
Flush the condensate trap.
z
Fill the condensate trap with water before re-installing it.
z
Check the condensate trap gasket for damage and
replace it if necessary.
z
Re-assemble all parts in reverse order of disassembly.
13.2 Checking and adjusting the gas/air-ratio
See chapter 9.8 "Checking and adjusting the gas/air ratio",
page 34.