EV terminal (external switching contact)
This terminal can be used for example for the safety switch
of floor heating. This protects the floor heating against too
high boiler water temperatures (external manual reset high
limit). The boiler is shut down when the external switching
contact is opened.
The normally closed contacts of a LWCO will shut down
burner operation but allow the pump to continue to operate
in case of a low water condition.
DWV
Terminal for connection of an external 3-way valve.
PK
Connector for the primary loop pump 120V 60Hz.
PS
Connector for the DHW tank pump 120V 60Hz.
PZ
Connector for the DHW recirculating pump 120V 60Hz.
Netz
Main power connector 120V 60Hz.
120-volt connections
CAUTION
Make sure that the power consumption of each
of the terminals 7 – 9 (see circuit diagram) does
not exceed 250 W or 5 Amp.