Dimensions and connections
4
10
Installation instructions Logamax plus GB142-24/30/45/60 • version 10/2007
Buderus • http://www.buderus.net
We reserve the right to make any changes due to technical modifications!
Fig. 4
Dimensions and connections for boiler GB142-45/60 (dimensions in inches)
AA (
A
)
AKO (
E
)
GAS (
D
)
=
=
=
Combustion air
Condensate water outlet, Ø 1.3” (Ø 32 mm)
Gas connection, ¾” NPT
LA (
B
)
RK (
G
)
VK (
F
)
WB (
C
)
=
=
=
=
Air intake
Return, Ø 1.0”
1
(Ø 25.4 mm)
Supply, Ø 1.0”
1
(Ø 25.4 mm)
Wall bracket
1
One Ø 1.0” (Ø 25.4 mm) inside x 1'' NPT threaded compression fitting is delivered enclosed.
20.7" (526 mm)
1.2" (30 mm)
16" (420 mm)
7.5" (190 mm)
28" (712 mm)
4.7" (119 mm)
4.3" (110 mm)
13.2" (335 mm)
35.4" (900 mm)
9.7" (246 mm)
6.2"
(158 mm)
0.25"
(6 mm)
1.8" (46 mm)
18.7" (475 mm)
> 6"
(150 mm)
> 4"
(100 mm)
2.2" (55 mm)
3" (75 mm)
3" (75 mm)
D E
F
G
A
B
C
4" (100 mm)
12" (300 mm)
20" (500 mm)
NOTICE
Observe the lateral minimum distances of the
boiler (12” = 300 mm) and the necessary
distances (24” (600 mm) at the front and
4” (100 mm) at the top) for removing the casing
and for servicing.
Closet clearances are:
4” (100 mm) to the right, 4” (100 mm) at the top
and 6” (150 mm) to the left.