3. FUNCTION SETTINGS
BAS-311H
21
Maintenance settings
No.
Setting
range
Settings
Setting details
Initial
value
Specification
limits
Run-in operation mode
0
Disable
1
Continuous operation (one work clamp up/down operation per cycle)
occurs while the start switch remains on.
Not raised and lowered when memory switch No. 001 is set to
"OFF".
2
Continuous operation (two work clamp up/down operations per
cycle) occurs while the start switch remains on.
Not raised and lowered when memory switch No. 001 is set to
"OFF".
750 0-3
3
Continuous operation (three work clamp up/down operations per
cycle) occurs while the start switch remains on.
Not raised and lowered when memory switch No. 001 is set to
"OFF".
0 None
Run-in operation stop time
751 0-3000
Units (ms), Increments of 10
200 None
Sewing machine ID code (Sewing data specified on SD card)
752 0-99
Folder specified
0 None