3. FUNCTION SETTINGS
BAS-311H
8
*1: If there are no valid sewing programs when memory switch No. 405 is set to "OFF", only the standard program numbers
are displayed. If it is set to "ON" when no programs have been registered, nothing is displayed (the display is skipped).
*2: If an F key which does not have a program registered to it is pressed, the key will be invalid. (The buzzer will sound
twice.)
No.
Setting
range
Settings Settings
details
Initial
value
Specification
limits
F key specifications
0
F keys become direct selection keys for sewing program numbers
(101 to 104).
1
F keys become direct selection keys for cycle program numbers
(C01 to C04).
*
Selection is possible when memory switch No. 400 is set to “ON”.
406
*
2
0-2
2
F keys become shortcut keys for program numbers which have been
assigned to the keys.
F1 … Setting number for memory switch No. 407
F2 … Setting number for memory switch No. 408
F3 … Setting number for memory switch No. 409
F4 … Setting number for memory switch No. 410
0 None
Assignment number to F1 key
407
100-999,
C01-C30
101 None
Assignment number to F2 key
408
100-999,
C01-C30
102 None
Assignment number to F3 key
409
100-999,
C01-C30
103 None
Assignment number to F4 key
410
100-999,
C01-C30
104 None