3. FUNCTION SETTINGS
BAS-311H
19
No.
Setting
range
Settings Setting
details
Initial
value
Specification
limits
Time from sensor turning on to sewing start when memory switch No. 560 is set
to "2"
561 0-999
Units (ms), Increments of 1
100
Pneumatic
2-step tension
OFF
Disable
564 ON/OFF
ON
2-step tension is used.
OFF None
Tension release force setting
0
Standard
(Tension release is open at the sewing end.)
1
Increases the force.
(Tension release is closed at the sewing end. When using threading
mode, it will be closed in approximately 5 minutes.)
565 0-2
2
Tension release force is set to the maximum.
(Tension release is closed at the sewing end. When using threading
mode, it will be closed in approximately 1 minute.)
0
(-3,-5)
1
(-7)
None
Upper thread tension during test feed
OFF
Upper thread tension not applied.
567 ON/OFF
ON
Upper thread tension applied.
OFF None
Detection timing for lower thread sensor (Not reset during initialization)
569 0-3
0: Sensor not used = 1: Before = 2: After = 3: Before and after
0 None
Wait time after lower thread detection is complete
570 1-99
Units (×10 ms), Increments of 1
30 None
Wait time for lower thread detection response
571 1-99
Units (×10 ms), Increments of 1
30 None
Output time for lower thread detection operation command signal
572 1-99
Units (×10 ms), Increments of 1
50 None