3. FUNCTION SETTINGS
BAS-311H
18
Device settings
No.
Setting
range
Settings Setting
details
Initial
value
Specification
limits
Needle cooler device
0
Disable
550 0-2000
100-
2000
Needle cooler device is used.
Continuous output time after sewing machine stops (ms)
Increments of 100
0
None
Upper thread tension release at the sewing start
0
Not released
551 0-3
1-3
Released during the specified number of stitches
0
None
Tension release timing during thread trimming
0
-3: Medium-weight material specifications
-5:
Heavy-weight material specifications
552 -80-8
-24
-7: Seatbelt specifications
0
(-3,-5)
-24
(-7)
None
Thread breakage sensor
OFF
Disable
554 ON/OFF
ON
Fiber-type thread breakage sensor is used.
OFF None
Thread breakage sensor detection sensitivity
OFF
5 stitches at sewing start, 3 stitches while sewing
555 ON/OFF
ON
10 stitches at sewing start, 3 stitches while sewing
OFF
None
Inner clamping device (Option output No.13) (Not reset during initialization)
0
Disable
1
Inner clamping device is used.
(Retract operation is carried out at the sewing end to prevent
interference with the needle.)
2
Inner clamping device is used.
(No retract operation at the sewing end)
556 0-3
3
Inner clamping device operates for 1/4 of the sewing pattern and
returns for the other 3/4.
(No retract operation)
0
None
Wiper device
0
Disable
1
Standard wiper device is used.
557 0-2
2
Pneumatic-type wiper device is used. (Option output No. 2)
1
None
External error monitoring input
OFF
Disable
558 ON/OFF
ON
Enabled (Option input No. 13 [AIRSW])
OFF
None
Operating indicator output
OFF
Disable
559 ON/OFF
ON
Option output No. 9 : Output ON while operating
Option output No. 10: ON during lower thread conversion and during
test mode
Option output No. 11: ON when error is generated
OFF
None
Automatic ejector
(Option output No. 3 output: Option input No. 1 = right sensor: Input No. 2 = left
sensor)
*
When this device is used, memory switch No. 002 should be set to "0".
0
Disable
1
Standard automatic ejector operation occurs.
2
Sewing starts when cassette sensor is ON.
560 0-3
3
Start switch is enabled even if cassette sensor is OFF.
0
Pneumatic