8. ADJUSTMENT
BAS-311H
88
8-5. Adjusting the needle bar height
3059B 3376B
3377B
Turn the pulley (1) in the direction of the arrow to move the needle bar to the lowest position. Then remove the rubber plug (3),
loosen the screw (4) and then move the needle bar up or down to adjust so that the second reference line from the bottom of
the needle bar (reference line A) is aligned with the lower edge of the needle bar bush (2).
*
If using a DP x 5 needle, use the highest reference line (reference line a).
8-6. Adjusting the timing and the driver needle guard
3359B
3360B
3059B
0135Q
3361B
1. Turn the pulley (1) in the direction of the arrow to raise the needle bar from the lowest position until the lowest reference
line on the needle bar (reference line B) is aligned with the lower edge of the needle bar bush (2).
*
If using a DP x 5 needle, align with reference line b which is the second reference line from the top.
2. Loosen the bolt (3).
3. Move the driver (4) sideways so that the rotary hook tip is aligned with the middle of the needle, and then move the driver
(4) back and forth so that it is touching the needle. Then tighten the bolt (3).
NOTE:
If the driver (4) crosses the needle more than necessary, it will cause problems with the thread tension.
Furthermore, if it does not cross the needle, skipped stitches or needle breakages may occur.
Center of the needle
Rotary hook