3. FUNCTION SETTINGS
BAS-311H
17
Program settings
No.
Setting
range
Settings Setting
details
Initial
value
Specification
limits
X-sewing area setting (Not reset during initialization)
460 0-150
Units (mm), Increments of 1
150 None
Y-sewing area setting (Not reset during initialization)
461 0-100
Units (mm), Increments of 1
100 None
Enlargement/reduction reference point
0
Zoom reference point is the center of the sewing frame.
1
Zoom reference point is the sewing start position.
2
Zoom reference point is the center of the sewing pattern.
3
Front of pattern center
4
Back of pattern center
5
Back-left corner of sewing area
6
Front-left corner of sewing area
7
Back-right corner of sewing area
462 0-8
8
Front-right corner of sewing area
0 None
The parallel movement amount is stored even when the power is turned off.
1
Movement amount is Initialized when program number or
enlargement/reduction ratio is changed and when power is turned
off.
2
Movement amount is Initialized when program number or
enlargement/reduction ratio is changed but not when power is
turned off.
465 1-3
3
Set separately for each program.
*
Disabled when memory switch No. 400 is set to "OFF".
(Parallel movement mode cannot be used.)
*
Select "1" or "2" when memory switch No. 400 is set to "OFF".
1 None
Retract point switching at parallel movement point
OFF
Disable
468 ON/OFF
ON
The position moved to by parallel movement is recorded as the
retract point.
OFF None