Error status #9 Work clamp does not rise.
Probable causes
Check/repair/adjust
Parts to be replaced
1. Incorrect work clamp home
position adjustment
a. Adjust the home position while referring to
“8-22. Adjusting the home position”.
b. Check if the work clamp/button clamp is
touching anything.
2. Incorrect mechanism adjustment
Check if the work clamp arm moves smoothly.
Work clamp arm assembly
Error status #10 Work clamp does not lower.
Probable causes
Check/repair/adjust
Parts to be replaced
1. Incorrect work clamp home
position adjustment
a. Adjust the home position while referring to
“8-22. Adjusting the home position”.
b. Check if the work clamp/button clamp is
touching anything.
2. Incorrect mechanism adjustment
Check if the work clamp arm moves smoothly.
Work clamp arm assembly
Error status #11 The TEST indicator does not light when the TEST key is pressed.
Probable causes
Check/repair/adjust
Parts to be replaced
Malfunction of panel PCB
Check that connector P3 (PANEL) is connected
to the motor PCB, and that connector P1 (MAIN)
is connected to the panel PCB.
Panel PCB assembly
Panel harness
Error status #12 The feed mechanism does not slowly move stitch by stitch during test feeding.
Probable causes
Check/repair/adjust
Parts to be replaced
1. Incorrect memory switch setting
Set memory switch No. 200 to OFF.
2. Malfunction of foot switch and
cord
See #4.
Error status #13 Quick feeding cannot be performed during test feeding.
Probable causes
Check/repair/adjust
Parts to be replaced
Malfunction of foot switch and cord
See #4.
Error status #14 The machine does not operate correctly for the set program test feeding.
Probable causes
Check/repair/adjust
Parts to be replaced
Malfunction of foot switch and cord