3. FUNCTION SETTINGS
BAS-311H
11
No.
Setting
range
Settings Settings
details
Initial
value
Specification
limits
Work clamp operation when
three-pedal foot switch
is set
(Can be set when memory switch No. 70 is set to "3". Not displayed at other
times.)
(Not reset during initialization)
1
[Standard]
Pneumatic method: The left pedal raises and lowers the left work
clamp, and the right pedal (center) raises and lowers the right work
clamp.
The start switch (right) starts the sewing machine.
Motor-driven method (Solenoid) : 1st step when left pedal is
depressed: 2nd step when right (center) pedal is depressed (invalid
for single step work clamp)
The start switch (right) starts the sewing machine.
None
2
[Independent home detection]
The right pedal (center) is used exclusively for detecting the home
position.
The left pedal raises and lowers the left and right work clamps, and
the start pedal (right) starts the sewing machine.
The start switch (right) starts the sewing machine.
Pneumatic
073 1-3
3
[Independent home detection]
The right pedal (center) is used exclusively for detecting the home
position.
The left work clamp only is raised and lowered when the left pedal is
depressed.
The start switch (right) lowers the right work clamp and starts the
sewing machine.
1
Pneumatic