![Bosch VIDEOJET connect 7000 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/bosch/videojet-connect-7000/videojet-connect-7000_operation-manual_47723018.webp)
Technical Data
Specifications
Specification
Value
Power requirements
100 VAC - 240 VAC (90 VAC - 264 VAC with tolerance
considered), 50/60 Hz; 56V output
Alarm inputs
Four (4) normal dry contacts (selectable N.O./N.C.)
One (1) monitored tamper alarm input, 2.2K ohm end-of-
line termination
Alarm outputs
Three (3) open collector outputs, 32 VDC, 150 mA
Audio
One (1) mono line in; one (1) mono line out
connector 3.5 mm stereo jack
signal line in 9 kohm typical, 5.5 Vpp max. 25
signal line out 3.0 Vpp at 10 kohm typical;
2.3 Vpp at 32 ohm typical;
1.7 Vpp at 16 ohm typical
Washer driver output
Dry contact relay, 250 V, 5 A
Communication
Three (3) 10BASE-T/100BASE-TX/1000Base-TX
If SFP fiber optic modules installed: two (2) 1000 BASE-
FX
Push button
Momentary switch to activate washer relay
Local storage
One (1) slot for optional CompactFlash (CF) memory
card, Type I / Type II, 32 GB max (user-supplied)
SFP (small form-factor pluggable) Two (2) slots for use with SFP-based fiber optic modules
(1GB only) as recommended in the section Optional
Accessories, page 12
Ingress Protection Rating/
Standard
IP66, IP67, Type 4
4
4.1
18
en | Technical Data
VIDEOJET connect 7000
2014.10 | 1.4 | F.01U.291.524