AutoDome Pendant Arm Mount

 Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 

11 

Pressurized Environmental Mounting Options 

The AutoDome Pressurized Environmental Housing must be mounted to the appropriate 

pendant mount. The pendant mount for the Pressurized Environmental Housing has been 

modified to remove the guide pins that serve as installation aids. You must mount the 

Pressurized Environmental Housing to the VGA-PRES-ARM 

CAUTION! 

DO NOT mount a Pressurized Environmental Housing to the VGA-PEND-ARM mounting option. 

This mounting option contains guide pins that are not compatible with the Pressurized 

Environmental Housing. Refer to item 1 on the images below: 

If your pendant arm contains these pins, 

DO NOT

 attempt to mount a Pressurized 

Environmental Housing to the mount. You must order the appropriate mounting option for the 

Pressurized Environmental Housing. 

Route Wires 

The VGA-PEND-ARM does not include a power supply. Incoming power supplies of 120 VAC or 

230 VAC must be routed through a power supply with an appropriate transformer to step 

down the voltage to 24 VAC before connecting to the VGA-PEND-ARM. Power wires must be 

routed to an appropriate power supply box through a separate conduit. 

All video, control, and alarm wires may be routed through a second conduit to the power 

supply then to the VGA-PEND-ARM or can be routed directly to the VGA-PEND-ARM through a 

conduit. 

WARNING! 

External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for 

US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in 

accordance to local country codes for all other countries. 

Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated 

Fuses are required as part of the building installation. A readily accessible 2-pole disconnect 

device with a contact separation of at least 3 mm must be incorporated. 

CAUTION! 

You must route the main power supply through a 120/230 VAC transformer (VG4-A-PSU1 or 

VG4-A-PSU2 power supply box) before connecting the power to a 24 VAC AutoDome. 

CAUTION! 

A VG5 600 Series AutoDome installation using coaxial cable to transmit video, either through a 

direct coaxial connection or through a fiber optic module, 

requires

 that you use the coaxial 

cable with ferrite shipped with the AutoDome pendant. The cable only connects to the 

AutoDome video output one way. Refer to 

Section 2.4.1 Coaxial Cable Connections, page 12

for more information. 

Bosch Security Systems, Inc. 

Installation Guide 

F.01U.250.238 | 1.0 | 2011.08 

                    Available from A1 Security Cameras 

    www.a1securitycameras.com email: [email protected]

Содержание VGA-PEND-ARM

Страница 1: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com AutoDome Pendant Arm Mount VGA PEND ARM VGA PEND WPLATE en Installation Guide ...

Страница 2: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Страница 3: ...ables 19 3 3 1 Using Coaxial Cable to Transmit Video and Control 19 3 3 2 Using UTP to Transmit Video and Control 20 3 3 3 Using Ethernet to Transmit Video and Control 21 3 3 4 Using Multi mode Fiber Optic to Transmit Video and Control 21 3 3 5 Using a Fiber Optic Ethernet Media Converter to Transmit Video and Control 22 3 4 Control only Cables 22 3 4 1 Controlling the AutoDome via Biphase 22 3 4 ...

Страница 4: ...pervised Alarm 31 4 3 2 Configuring a Normally Closed Non supervised Alarm 32 4 4 Alarm Outputs 32 4 4 1 Configuring a Dry Contact Relay 32 4 4 2 Configuring an Open Collector Output 32 F 01U 250 238 1 0 2011 08 Installation Guide Bosch Security Systems Inc Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Страница 5: ... but a moist fluff free cloth or leather shammy may also be used Do not use liquid cleaners or aerosol cleaners 2 Water Do not use this unit near water for example near a bathtub washbowl sink laundry basket in a damp or wet basement near a swimming pool in an outdoor installation or in any area classified as a wet location To reduce the risk of fire or electrical shock do not expose this unit to ...

Страница 6: ...e personnel when any damage to the equipment has occurred such as the power supply cord or plug is damaged exposure to moisture water and or inclement weather rain snow etc liquid has been spilled in or on the equipment an object has fallen into the unit unit has been dropped or the unit cabinet is damaged unit exhibits a distinct change in performance unit does not operate normally when the user ...

Страница 7: ... installation of CATV systems SELV All the input output ports are Safety Extra Low Voltage SELV circuits SELV circuits should only be connected to other SELV circuits Because the ISDN circuits are treated like telephone network voltage avoid connecting the SELV circuit to the Telephone Network Voltage TNV circuits System ground Safety ground System video ground is indicated by the symbol Safety po...

Страница 8: ...le redundant recording systems and a procedure to back up all analog and digital information Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly Note This manual has been compiled w...

Страница 9: ...ers Mounting Plate VGA PEND WPLATE Optional Mounting Accessories The following table lists the optional parts you may need for attaching a Pendant Arm to a Wall Corner or Mast Mounting Options Part Numbers Pendant Arm with wiring no power supply VGA PEND ARM Pendant Arm with wiring no power supply for a Pressurized Environmental Housing VGA PRES ARM Corner Mount Plate VG4 A 9542 Mast Mount Plate V...

Страница 10: ...tly earthed metal conduits 3 Route all rough wiring including power control video coax alarms I O relay I O and fiber optic cabling Refer to Section 3 Cable and Wire Standards page 19 for video and control protocol methods 4 Analog AutoDome If you plan to use the RS232 or RS485 protocol to control the AutoDome refer to Section 3 4 2 Controlling the AutoDome via the RS232 Protocol page 24 for instr...

Страница 11: ...te conduit All video control and alarm wires may be routed through a second conduit to the power supply then to the VGA PEND ARM or can be routed directly to the VGA PEND ARM through a conduit WARNING External interconnecting cables are to be installed in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I CSA C22 1 for CAN application and in accordance to local co...

Страница 12: ...onnecting the power to a 24 VAC AutoDome WARNING A stud diameter of 6 4 mm 1 4 inch to 8 mm 5 16 inch able to withstand a 120 kg 265 lb pull out force is recommended The mounting material must be able to withstand this pull out force For example 19 mm 3 4 inch minimum for plywood 1 For a Corner installation a Secure the Corner Plate to the wall corner using four 4 studs not included b Secure the M...

Страница 13: ...ounting Plate through the empty conduit hole as shown below 3 Ensure that the mounting plate is secure Attach the Pendant Arm to the Mounting Plate The bottom hinge pin of the Pendant Arm is provided with a Hinge Pin Stop to hold the hinge open while attaching the arm to the Mounting Plate 1 Compress the bottom hinge pin by pushing the pin lever downward and rotating it behind the Hinge Pin Stop F...

Страница 14: ...late Refer to Figure 2 2 above for an illustration 4 Once you have the hinges aligned release the top hinge pin to engage its mating hinge on the Mounting Plate Then release the bottom hinge pin from the Hinge Pin Stop to lock the Pendant Arm to the Mounting Plate Route and Connect Wires to a Power Supply Box The illustration below depicts the power and control cables connected to the Pendant Arm ...

Страница 15: ...nput conduit holes 4 Connect the incoming 24 VAC power wires to the 5 pin 24 VAC Power In mating connector supplied with the Mounting Plate kit for the Dome and for the Heater CAUTION You must route the main power supply through a 120 230 VAC transformer VG4 A PSU1 or VG4 A PSU2 power supply box before connecting the power to a 24 VAC AutoDome 5 Attach the grounding spade from the 5 pin mating con...

Страница 16: ... to the UTP Video Ethernet cable cable 5 Refer to Section 3 Cable and Wire Standards page 19 for detailed wire and connection information 15 Connect the outgoing alarm wires to the flying leads coming from the 4 pin Alarm Outputs cable cable 6 16 Connect the incoming alarms wires to the flying leads coming from the 6 pin Alarm Inputs cable cable 7 17 Analog AutoDome Connect the incoming serial com...

Страница 17: ...m 1 Tilt the bottom of the dome toward the pendant arm base and place the mounting hook located on top of the dome housing over the recessed hinge pin of the arm a b Figure 2 5 Attach Pendant to Arm 1 Tilt up 2 Hook and drop 2a Recessed Hinge Pin 2b Dome Connector 3 Rotate down to engage dome connector 4 Tighten the two 2 mounting screws to a minimum torque of 10 12 N m 90 105 in lbs Bosch Securit...

Страница 18: ...feel any resistance when rotating the dome housing or when engaging the connector stop immediately and start over 4 Hold the Pendant housing in position while tightening the two 2 5 mm Allen head mounting screws on top of the housing to 10 12 N m 90 105 in lbs CAUTION You must tighten the two mounting screws to a minimum torque of 10 12 N m 90 105 in lbs to ensure a proper seal between the arm and...

Страница 19: ...ndard heater module Add Add 16 W if using VG4 SHTR XT kit 3 3 Video and Control Cables 3 3 1 Using Coaxial Cable to Transmit Video and Control CAUTION 600 Series AutoDome If you are using coaxial cable to transmit video and data between the AutoDome and the head end you must use the coax cable with ferrite included in the AutoDome packaging You must connect the incoming coax cable from the head en...

Страница 20: ...ly a Coax to UTP cable converter is required at the head end of the system Bilinx control data can also be sent over the same two video wires 1 2 Bilinx is a Bosch 2 way communication protocol that allows remote control configuration and updates over a passive UTP cable VG5 Series AutoDomes feature cable compensation or Pre Comp which extends the normal range of control from the head end WARNING D...

Страница 21: ...c to Transmit Video and Control Fiber Optic kits available for AutoDome 100 and 600 Series cameras transmit both video and Biphase control over an analog singlemode or multimode fiber Multimode Fiber Type 50 125 µm 62 5 125 µm low loss multimode glass fiber Maximum Distance 4 km 2 5 miles Minimum Bandwidth 20 MHz Video 850 nm Control 1300 nm Requirement Bosch LTC 4629 Fiber Receiver at controller ...

Страница 22: ...fiber standard ITU T G 651 Fiber Type SMF 8 10 125 µm SMF Must meet or exceed fiber standard ITU T G 652 Maximum Distance 60 km 37 3 miles Requirement Media converter receiver CNFE2MC IN at controller end of system Terminal Connection Duplex LC or Single SC 3 4 Control only Cables 3 4 1 Controlling the AutoDome via Biphase Shielded 2 wire half duplex multi drop 5000 ft cable limit Biphase is the s...

Страница 23: ...n where multiple domes are connected in series the 100 Ω resistor must be removed from all but the last dome You can daisy chain a maximum of four 4 AutoDomes 100 Ω Figure 3 3 Connections for a Daisy Chain Configuration 1 C Biphase 9 Dome 3 2 C Biphase 10 Dome 2 3 Earth Ground 11 Dome 1 4 RxD 12 Head End Biphase 5 TxD 13 C Biphase 6 Signal Ground 14 C Biphase 7 Last Dome Data In Out 15 Shield 8 P1...

Страница 24: ...After making the wire connections for RS232 operation reposition the slide switch located on the CPU Module to the camera head inward and away from the LEDs Wire Type 3 wire TXD RXD common Distance 15 m 50 ft Maximum Baud Rate 57 6 Kb Voltage 15 V Termination 100 Ω Slide Switch Away from LEDs factory default Figure 3 4 1 2 3 4 5 6 Connections for RS232 Operation C Biphase C Biphase Earth Ground Rx...

Страница 25: ...ire shield must be tied to signal at both ends if 2 wire twisted pair is used After connecting the wires for RS485 operation make sure the slide switch on the main board to the camera head is positioned toward the LEDs default CAUTION Bosch recommends that multiple RS485 connections be arranged as a connected series of point to point multi dropped nodes as a line or as a bus It is not recommended ...

Страница 26: ... from the pendant housing Fiber Optic Module with an RS232 RS422 Controller An AutoDome with a fiber optic module is prewired to operate with Biphase signals only This section describes the procedures necessary to control a VG5 series AutoDome fitted with a fiber optic kit using an RS232 controller or a Pelco RS422 controller To control a VG5 Series Autodome from an RS232 or from a Pelco RS422 con...

Страница 27: ...five wires from the green Serial Communications wire mating connector Ensure that the insulation covers each wire to avoid wires from touching 5 Cut back the insulation on the blue ground wire and on the green RxD wire enough to be able to connect these wires back into the P106 connector 6 Connect the blue ground wire to the C pin on the P106 connector 7 Connect the green RxD wire to the C pin on ...

Страница 28: ...apable of receiving line input audio signals and transmitting it over a network The audio signal is transmitted one way and in sync with the video signals Audio Line Input Specifications Max Input Voltage 5 5 Vpp Impedance 9K Ω Sample Rate 8 K Hz 16 Bit mono Shield Bare copper braid 95 coverage Internal gain level adjustment is available Wire Specifications Wire Type Coax3 recommended Distance 10 ...

Страница 29: ...s the connections for audio over an IP network Figure 3 10 Connections for audio over an Ethernet network 1 C Biphase 7 AutoDome Data In Out 2 C Biphase 8 P105 P106 Connector 3 Earth Ground 9 Audio Out 4 RxD 5 TxD 6 Signal Ground NOTICE Refer to the VG5 700 Series AutoDome User Manual for configuring and using audio over an IP Ethernet network Bosch Security Systems Inc Installation Guide F 01U 25...

Страница 30: ...hort or a break in the alarm s circuit can trigger the tamper signal Configuring Supervised Alarms inputs 1 and 2 To configure Alarm 1 or 2 pin 5 or 6 for supervision you must install a 2 2 K end of line resistor in the circuit Then you program the alarms through the AutoDome main menu to either Normally Open Supervised N O S or Normally Closed Supervised N C S NOTICE Only Alarms 1 and 2 pins 5 or...

Страница 31: ...up and set Alarm Input 1 Dry Contact 3 Dome Connector 2 Alarm 1 or 2 only Pin 5 or 6 4 Ground Pin 7 to N C S See the table below for contact and condition details AutoDome Programmed N C S Contact Alarm Condition Open Alarm Closed Normal Short Tamper 4 3 Configuring Non supervised Alarms inputs 1 through 7 You can configure alarms 3 through 7 as non supervised Normally Open N O or Normally Closed ...

Страница 32: ...AutoDome incorporates two 2 types of alarm outputs a dry contact relay and three 3 open collector outputs or transistor outputs 4 4 1 Configuring a Dry Contact Relay The dry contact relay acts like an on off switch It has a maximum voltage rating of 2 A 30 DC 1 Connect the appropriate stripped wire to the AutoDome COM connector 2 Connect the appropriate stripped wire to the N O or N C connector de...

Страница 33: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Страница 34: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Страница 35: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Страница 36: ...urity Systems Inc 850 Greenfield Road Lancaster PA 17601 U S A www boschsecurity com Bosch Security Systems Inc 2011 Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Отзывы: